Integrated Optic Surface Plasmon Resonance Measurements in a Borosilicate Glass Substrate
نویسندگان
چکیده
The surface plasmon resonance (SPR) technique is a well-known optical method that can be used to measure the refractive index of organic nano-layers adsorbed on a thin metal film. Although there are many configurations for measuring biomolecular interactions, SPR-based techniques play a central role in many current biosensing experiments, since they are the most suited for sensitive and quantitative kinetic measurements. Here we give some results from the analysis and numerical elaboration of SPR data from integrated optics experiments in a particular borosilicate glass, chosen for its composition offering the rather low refractive index of 1.4701 at 633 nm wavelength. These data regard the flow over the sensing region (metal window) of different solutions with refractive indexes in the range of interest (1.3÷1.5) for the detection of contaminants in aqueous solutions. After a discussion of the principles of SPR, of the metal window design optimization by means of optical interaction numerical modeling, and of waveguide fabrication techniques, we give a description of system setup and experimental results. Optimum gold film window thickness and width in this guided-wave configuration has been for the first time derived and implemented on an integrated optic prototype device. Its characterization is given by means of the real time waveguide output intensity measurements, which correspond to the interaction between the sensing gold thin film window and the flowing analyte. The SPR curve was subsequently inferred. Finally, a modified version of the device is reported, with channel waveguides arranged in a Y-junction optical circuit, so that laser source stability requirements are lowered by a factor of 85 dB, making possible the use of low cost sources in practical applications.
منابع مشابه
Substrate Effect on Plasmon Resonance of a Gold Nanoparticle Embedded Amorphous BaTiO3 Film
Two sets of gold nanoparticles (NP) embedded in amorphous BaTiO3 films were prepared by sol-gel method using spin coating. Sample (1) is having BaTiO3 sol with 0.025 gm of Chloroauric acid dissolved in 10 ml of propan-2-ol, while sample (2) is having 0.086 gm of Chloroauric acid in the same amount of propan-2-ol. The films have been deposited on various substrates like borosilicate glass and fu...
متن کاملOptimization of Sensitivity and Stability of Gold/Silver bi-Layer Thin Films Used in Surface Plasmon Resonance Chips
The aim of this study is experimental assay of sensitivity and stability of a bimetallic silver/gold SPR sensor chip. This chip utilizes the sensitivity of the silver and the stability of the gold. Moreover, the Silver layer (instead of usual Cr or Ti layer) was used as an adhesive intermediate layer between the Gold layer and the glass substrate. The optimization of the Gold/Silver thickness u...
متن کاملNear orthogonal launch of SPR modes in Au films.
We report the excitation of a surface plasmon resonance (SPR) close to the orthogonal axis of a gold (Au) film on borosilicate glass. Direct spectroscopic measurement of SPR shifts using different liquids are made at ∼5° incidence within a reflection spectrophotometer. The proposed mechanism to establish coupling and plasmon localization is the scattering of light able to penetrate across the f...
متن کاملIntegrated opto-chemical sensors
Integrated opto-chemical sensors have promising prospects, for example by having the potential to be realized as very sensitive small monolithic smart multisensor systems with a digital signal output. Here the main accent will be laid on the optical principles underlying chemo-optical waveguiding sensors, focusing on linear evanescent field sensors. Sensing principles and systems based on inter...
متن کاملIn Vitro Biocompatibility Test of Multi-layered Plasmonic Substrates with Flint Glasses and Adhesion Films
Since in vitro neural recording and imaging applications based on a surface plasmon resonance (SPR) technique have expanded dramatically in recent years, cytotoxicity assessment to ensure the biosafety and biocompatibility for those applications is crucial. Here, we report the cytotoxicity of the SPR substrate incorporating a flint glass whose refractive index is larger than that of a conventio...
متن کامل