Endo-Modell rotating-hinge total knee for revision total knee arthroplasty.

نویسندگان

  • Alessandro Bistolfi
  • Federica Rosso
  • Maurizio Crova
  • Giuseppe Massazza
چکیده

The goal of this study was to analyze the clinical and radiographic results and the survival rate of a series of rotating-hinge implants used for revision total knee arthroplasties in mild and severe instability. Between December 1991 and June 2004, fifty-three revision total knee arthroplasties were performed using the Endo-Modell (Waldemar LINK GmbH and Co, Hamburg, Germany) rotating-hinge prosthesis; 7 (13.2%) patients underwent partial revision of a previous Endo-Modell. All patients were evaluated preoperatively, 3 and 6 months postoperatively, and annually thereafter using the Hospital for Special Surgery (HSS) knee score and the Knee Society Roentgenographic Evaluation System (KS-RES). Mean follow-up was 155.2±40.1 months (range, 78-240 months), with 32 patients examined at the final follow-up. All HSS knee scores increased from preoperatively to last follow-up. No statistically significance differences were found in the HSS knee scores between septic and aseptic revisions and between total or partial revisions. Progressive radiolucent lines were detected in 8 (25%) patients. Implant failure occurred in 11 (20.7%) patients; the cumulative survival of the implants was 80.4% at 150 months for the final 32 patients. The authors recommend use of this implant for revision total knee arthroplasty, especially in patients with severe instability and bone loss.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Results with 98 Endo-Modell rotating hinge prostheses for primary knee arthroplasty.

Rotating hinge knee prostheses have been developed as an advancement of the fixed hinge models. Some authors suggest that this type of prosthesis is associated with a greater risk of aseptic loosening because of the increased stresses to the bone-prosthesis interface; therefore, they are scarcely used as primary implants. The current authors evaluated of a series of 98 rotating hinge knee arthr...

متن کامل

Rotating-hinge total knee for revision total knee arthroplasty.

Rotating-hinge knee implants are used for revision total knee arthroplasty in patients with severe ligament instability and bone loss. This study evaluated the outcomes of a series of rotating-hinge knees. Thirty-one NexGen Rotating Hinge Knees (Zimmer, Warsaw, Indiana) were implanted in 29 patients (2 bilateral), with an average age of 72.8 years. Indications for surgery were aseptic loosening...

متن کامل

Rotating Hinge Total Knee Arthroplasty RT-PLUS Solution: A Clinical and Radiographic Follow-Up

Background: In total knee arthroplasty (TKA), there is still controversy surrounding the preferable prosthetic design and required amount of constraint. Indication for rotating hinge TKA includes primary and revision arthroplasty, with contradictory results. We present the first mediumto long-term results with the rotating hinge knee prosthesis RT-PLUS SOLUTION (Smith & Nephew Orthopaedics, Baa...

متن کامل

Genu recurvatum as a complication after total knee arthroplasty.

A 73-year-old female patient underwent total knee arthroplasty for arthrosis. After surgery, recurvatum instability over 55 degrees occurred. Two years later, primary endoprosthesis was removed and a revision endoprosthesis implanted. However, complete deformity occurred again. Two years later, the thickest revision polyethylene tibial implant was implanted on the same endoprosthesis. In spite ...

متن کامل

Better Outcomes in Severe and Morbid Obese Patients (BMI > 35 kg/m2) in Primary Endo-Model Rotating-Hinge Total Knee Arthroplasty

The Endo-Model rotating-hinge prosthesis is preferably indicated as a primary implant in patients with advanced axial deviation of the lower limbs or unstable knees with severe bone defects. Outcomes were studied in 111 knees, operated in a three-year period; the mean followup was 28 months. Joint balance enhancement and limbs mechanical axis correction were achieved after surgery. There were 6...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 36 10  شماره 

صفحات  -

تاریخ انتشار 2013