A new approach to noninvasive evaluation of aortic regurgitant fraction by two-dimensional Doppler echocardiography.

نویسندگان

  • A Kitabatake
  • H Ito
  • M Inoue
  • J Tanouchi
  • K Ishihara
  • T Morita
  • K Fujii
  • Y Yoshida
  • T Masuyama
  • H Yoshima
چکیده

The aortic regurgitant fraction was estimated noninvasively in 20 patients with aortic regurgitation from systolic aortic and pulmonary volume flow determined by duplex Doppler echocardiography. By assuming that an excess of the aortic volume flow (AF) compared with the pulmonary volume flow (PF) is due to aortic regurgitant flow, the aortic regurgitant fraction (RF) was calculated as follows: RF(%) = (AF - PF)/AF X 100. The aortic and pulmonary volume flows were determined as products of systolic integrals of ejection flow velocities and cross-sectional areas of the left and right ventricular outflow tracts, respectively. The Doppler estimate of the regurgitant fraction was compared by semiquantitative grading (1+ to 4+) by cineaortography and with the measurement of regurgitant fraction by catheter technique. The mean Doppler-determined aortic regurgitant fraction was 2.4% for normal subjects, 28.0% for the patients with 1+, 32.6% for the patients with 2+, 53.3% for the patients with 3+, and 62.4% for the patients with 4+. A fair correlation was found between Doppler estimates of regurgitant fraction and semiquantitative cineaortographic grades (r = .80, p less than .01). In the patients without associated mitral regurgitation, a close correlation was observed between Doppler and catheter estimates of regurgitant fraction (r = .96, p less than .01; y = 1.0x - 0.08). In the patients with associated mild mitral regurgitation, however, Doppler estimates of regurgitant fraction substantially underestimated those determined by the conventional catheter technique, which cannot separately quantitate the aortic regurgitant fraction in the presence of mitral regurgitation. These observations indicate that the proposed Doppler technique provides a useful method to evaluate the aortic regurgitant fraction specifically regardless of the presence of associated mitral lesions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MITRAL REGURGITATION Quantitation of mitral regurgitation by Doppler echocardiography

The evaluation and care of patients with mitral regurgitation would be facilitated by an easy, reproducible and noninvasive method that could quantitate the hemodynamic burden. In this study, we describe a new Doppler echocardiographic method that measures the regurgitant fraction and we compare it with angiographic and scintigraphic methods. A total of 27 patients with mitral regurgitation wer...

متن کامل

Determination of regurgitant fraction in isolated mitral or aortic regurgitation by pulsed Doppler two-dimensional echocardiography.

Measurements of mitral and aortic valve flows were obtained with two-dimensional Doppler echocardiography in 25 patients with isolated mitral (n = 19) or aortic (n = 6) regurgitation and regurgitant fraction was calculated as the difference between the two flows divided by the flow through the regurgitant valve. Results were compared with measurements of regurgitant fraction determined by combi...

متن کامل

Noninvasive evaluation of aortic regurgitation by continuous-wave Doppler echocardiography.

Continuous-wave Doppler echocardiography was used to examine the aortic regurgitant flow velocity pattern in 32 patients with aortic regurgitation (AR) and 10 patients without AR. The aortic regurgitant flow velocity patterns, characterized by a rapid rise in flow velocity immediately after closure of the aortic valve, high peak flow velocity, and a gradual deceleration until the next aortic va...

متن کامل

A new approach to noninvasive evaluation of aortic regurgitant fraction by two - dimensional Doppler

The aortic regurgitant fraction was estimated noninvasively in 20 patients with aortic regurgitation from systolic aortic and pulmonary volume flow determined by duplex Doppler echocardiography. By assuming that an excess of the aortic volume flow (AF) compared with the pulmonary volume flow (PF) is due to aortic regurgitant flow, the aortic regurgitant fraction (RF) was calculated as follows: ...

متن کامل

Measurement of aortic regurgitation by Doppler echocardiography.

In an attempt to develop a new approach to the non-invasive measurement of aortic regurgitation, transmitral volumetric flow (MF) and left ventricular total stroke volume (SV) were measured by Doppler and cross sectional echocardiography in 23 patients without aortic valve disease (group A) and in 26 patients with aortic regurgitation (group B). The transmitral volumetric flow was obtained by m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 72 3  شماره 

صفحات  -

تاریخ انتشار 1985