Methods of measuring the iridocorneal angle in tomographic images of the anterior segment of the eye
نویسندگان
چکیده
INTRODUCTION This paper presents the problem of automatic measurement of the iridocorneal angle in tomographic images of the anterior segment of the eye. It includes the results of the comparison of well-known methods for measuring the iridocorneal angle with new methods, proposed in this paper. All these methods concern tomographic image analysis and processing. MATERIAL AND METHOD In total, approximately 100'000 tomographic images (from about 6'000 patients) were analysed. They were obtained using two devices: SOCT Copernicus (Optopol Tech. SA, Zawiercie, Poland) and Visante OCT (Carl Zeiss Meditec, Inc, Dublin, California, USA). The patients, aged 12 to 78 years with varying degrees of the iridocorneal angle pathology, were from the region of Silesia, Poland. The images were in DICOM or RAW formats and analysed in the software developed by the authors for the purposes of this study. RESULTS The results indicate that the measurement method proposed by the authors, which is based on the calculation of the minimum distance between the iris and the cornea in the adopted area, is the most accurate. For this method sensitivity was 0.88, specificity 0.89 and the area under the Receiver Operating Characteristic curve (AUC) was 0.88. The other known methods for measuring the iridocorneal angle gave worse results, that is, for example, for the measurement of the distance between the iris and the cornea AUC = 0.87, sensitivity = 0.86 and specificity = 0.71. For another well-known method of measuring the iridocorneal angle AUC = 0.77, sensitivity = 0.82 and specificity = 0.61. CONCLUSIONS The study proved that the proposed method of measuring the minimum distance between the iris and the cornea within the adopted area is the most effective in the classification of the iridocorneal angle in patients with a high degree of pathology of all the compared measurement methods based on tomographic images. However, it requires fully automated measurement.
منابع مشابه
Secondary glaucoma due to anterior chamber lipoma and uveitis in a Pekingese dog
The present study introduces a rare case with secondary glaucoma due to anterior chamber lipoma and uveitis in a Pekingese dog in Iran. A four-year-old castrated male Pekingese dog was referred to the private clinic with impaired vision of the left eye, pain, rubbing the left eye onto carpet, presence of a milkycoloured mass into the anterior chamber, and loss of appetite. The clinical examinat...
متن کاملANTERIOR MEGALOPHTHALMOS
Anterior megalophthalmos is a developmental anomaly of the anterior ocular segment. This is an X-linked recessive disease and manifests as bilateral enlarged corneas, open iridocorneal angle, hypoplastic iris and dislocation and opacification of an apparently small lens. We have also observed obvious vitreoretinal degeneration in our patients. What may threaten visual acuity later is an op...
متن کاملQuantitative evaluation of anterior segment parameters in the era of imaging.
PURPOSE To review the parameters for quantitative assessment of the anterior segment and iridocorneal angle and to develop a comprehensive schematic for the evaluation of angle anatomy and pathophysiology by high-resolution imaging. METHODS The published literature of the last 15 years was reviewed, analyzed, and organized into a construct for assessment of anterior segment processes. RESUL...
متن کاملOptical Coherence Tomography as a Tool for Ocular Dynamics Estimation
PURPOSE The aim of the study is to demonstrate that the ocular dynamics of the anterior chamber of the eye can be estimated quantitatively by means of optical coherence tomography (OCT). METHODS A commercial high speed, high resolution optical coherence tomographer was used. The sequences of tomographic images of the iridocorneal angle of three subjects were captured and each image from the s...
متن کاملRepeatability of Ocular Measurements with a Dual-Scheimpflug Analyzer in Healthy Eyes
PURPOSE To assess the repeatability of the Galilei dual Scheimpflug analyzer (GDSA) in anterior segment examination. METHODS Fifty-two eyes from 52 healthy volunteers were prospectively and consecutively recruited. Anatomic, axial, refractive, and instantaneous parameters were measured with GDSA to provide a complete characterization of the anterior segment. Repeatability was assessed calcula...
متن کامل