Simultaneous Spectrophotometric Determination of Vanadium(V) and Iron(III) in Micellar Medium by H-Point Standard Addition Method

نویسندگان

  • Reza Tabaraki
  • Elham Heidarizadi
چکیده

H-Point Standard Addition Method (HPSAM) was applied for the simultaneous determination of V(V) and Fe(III). The method is based on the complex formation of V(V) and Fe(III) with chromazurol S (CAS) in acidic media and in the presence of cetyltrimethylammonium bromide (CTAB) as a micellizing agent. Acidic media and the presence of a micellar system improve selectivity and sensitivity. Fe (III) and V (V) could be determined simultaneously in the range of 0.1-2 and 0.2-2 μg / mL, respectively, and with the ratio 1:20 to 10:1 Fe(III)/V(V) in the mixed samples. The proposed method was successfully applied to the simultaneous determination of Fe(III) and V(V) in tap, river, saliva and plasma samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Spectrophotometric Determination of Vanadium(V) and Iron(III) in Micellar Medium by H-Point Standard Addition Method

H-Point Standard Addition Method (HPSAM) was applied for the simultaneous determination of V(V) and Fe(III). The method is based on the complex formation of V(V) and Fe(III) with chromazurol S (CAS) in acidic media and in the presence of cetyltrimethylammonium bromide (CTAB) as a micellizing agent. Acidic media and the presence of a micellar system improve selectivity and sensitivity. Fe (I...

متن کامل

Simultaneous Spectrophotometric Determination of Iron, Cobalt and Copper by Partial Least-Squares Calibration Method in Micellar Medium

Iron, cobalt and copper are metals, which appear together in many real samples, both natural and artificial. Recently a classical univariate micellar colorimetric method has been developed for determination of these metal ions. The organized molecular assemblies such as micelles are used in spectroscopic measurements due to their possible effects on the systems of interest. The ability of mi...

متن کامل

Simultaneous Spectrophotometric Determination of Iron, Cobalt and Copper by Partial Least-Squares Calibration Method in Micellar Medium

Iron, cobalt and copper are metals, which appear together in many real samples, both natural and artificial. Recently a classical univariate micellar colorimetric method has been developed for determination of these metal ions. The organized molecular assemblies such as micelles are used in spectroscopic measurements due to their possible effects on the systems of interest. The ability of mi...

متن کامل

Simultaneous Kinetic Spectrophotometric Determination of Hydrazine and Isoniazid Using H-Point Standard Addition Method and Partial Least Squares Regression in Micellar Media

The present study describes the application of simultaneous kinetic spectrophotometric determination of hydrazine (HZ) and isoniazid (INH), using H-point standard addition method (HPSAM) and partial least squares (PLS) calibration. The methods are based on the difference observed in the rate of iron (III) reduction with HZ and INH, in the presence of 2,2'-bipyridine (Bpy) and the subsequent com...

متن کامل

Flow injection analysis for oxidation state speciation of vanadium(IV) and vanadium(V) in natural water.

A sensitive and simultaneous spectrophotometric flow injection method for the determination of vanadium(IV) and vanadium(V) is proposed. The method is based on the effect of ligands such as 2,4,6-tris(2-pyridyl)-1,3,5-triazine (TPTZ) and diphosphate on the conditional redox potential of iron(III)/iron(II) system. A four-channel flow system is assembled. In this flow system, diluted hydrochloric...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014