Myocardial ASL Perfusion Imaging Using Pulsed 2D Tagging of the Proximal Aorta

نویسندگان

  • Z. Zun
  • E. C. Wong
  • K. S. Nayak
چکیده

Introduction Myocardial blood flow (MBF) measurement using arterial spin labeling (ASL) [1-4] suffers from a large apparent ASL signal in the LV blood pool due to inadvertent tagging of blood in the LA and/or LV. A high LV signal adjacent to myocardium may interfere with MBF measurements because of partial voluming and k-space truncation, and is a potential source of artifact, physiological noise, and MBF measurement error [5]. We present a new pulsed tagging method using a 2D spatially selective adiabatic inversion of the proximal aorta, and compare it with conventional pulsed ASL. Methods 2D Tagging Pulse: Our approach uses 2D selective inversion pulses oriented perpendicular to a standard three-chamber view, tagging blood in the proximal aorta while leaving the LA and LV undisturbed. We utilized the strategy of Conolly et al [6] to design 2D spatially selective adiabatic inversion pulses, and further reduced the pulse duration and peak B1 using the VERSE transform [7]. Fig. 1 shows our initial design. The composite pulse used 24 subpulses, each a small tip SLR pulse [8] with a time-bandwidth product of 3 and a duration of 0.5 ms prior to VERSE transformation. The overall sech envelope [9] has shape parameter μ = 2.5. The gradient waveform uses a flyback EPI trajectory for insensitivity to flow effects and timing errors. The overall duration of the pulse is 21 ms, which is short compared to the T2 of arterial blood (275 ms). Experimental Setup: The cardiac gated pulse sequence is illustrated in Fig. 2. Twodimensional selective inversion occurs immediately after the aortic valve closes, and imaging is centered at mid-diastole in the following heartbeat, both determined by a CINE scout scan. One pair of control and tagged images was acquired 6 s apart during a single breath-hold, and six breath-holds (8-10 sec each) were performed for signal averaging. Image acquisition was performed using a snapshot 2DFT balanced SSFP sequence with 3.2 ms TR and 50° flip angle. In each study, a single mid-short axis slice was imaged using a 96×96 matrix over a 20-24cm isotropic FOV, with 10mm slice thickness. Experiments were performed in three healthy volunteers on a GE Signa 3.0 T EXCITE with an 8-channel cardiac array coil. For a comparison, conventional pulsed ASL using 1D adiabatic inversion was performed as well in the same subjects with the same imaging parameters. Quantification: Regions of septal myocardium were manually segmented for each breathhold. We assumed that the 2D inversion tags all the blood at the root of the aorta that will travel into the coronaries during the following diastole, and hence used the equation MBF = (C-T)/(2α⋅C⋅RR⋅exp(-Ti/T1)) derived from Buxton’s general kinetic model [10] to arrive at the average perfusion rate over one R-R interval, where C, T, α, RR, Ti, and T1 refer to the mean myocardial signal in the control and tagged images, inversion efficiency, R-R interval, inversion time, and T1 of blood. Results Figure 3 illustrates in-vivo 1D and 2D tag profiles and corresponding ASL difference images for one representative subject. Tag profiles were measured by dividing two snapshot images (2DFT gradient echo, center-out view order); images with and without inversion pulse immediately prior to imaging. Table 1 contains the results from all subjects. The average inversion efficiency of 2D tagging was 67 %, and the residual LV signal on difference image of 1D tagging was reduced by 78 % using 2D tagging. We estimated MBF measurements considering this inversion efficiency, and estimated the confidence which is a probability of MBF measurement error being < 0.1 ml/ml/min based on Gaussian model of physiological noise. Using 2D tagging, MBF estimates decreased by 47 %, and measurement confidence increased from 37 % to 53%. Discussion 2D spatially selective adiabatic inversion pulses can be used to efficiently tag blood in the proximal aorta while leaving the LA and LV unperturbed. These pulses achieved inversion efficiency only 12% lower than that of 1D inversions, and may be improved by further optimization of the pulse parameters. This approach also improved the confidence in the measured MBF values, suggesting that the spurious LV signal is an important source of physiological noise in myocardial ASL. We are currently investigating the reason for reduced MBF estimates. References [1] Poncelet BP et al, MRM 41:510, 1999. [2] Wacker CM et al, JMRI 18:555, 2003. [3] An J et al, 13 ISMRM p253, 2005. [4] Zhang H et al, MRM 53:1135, 2005. [5] Zun Z et al, MRM submitted, 2008. [6] Conolly SM et al, MRM 24:302, 1992. [7] Conolly SM et al, JMR 78:440, 1988. [8] Pauly JM et al, IEEE TMI 10:53, 1991. [9] Silver MS et al, Phys. Rev. A 31:2753, 1985. [10] Buxton RB et al, MRM 40:383, 1998. scan 1D tagging 2D tagging Inv. effi. LV signal MBF Conf. Inv. effi. LV signal MBF Conf.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative Imaging of Perhsion Using a Single Subtraction (QUIPSS and QUIPSS

In the pulsed arterial spin labeling (ASL) techniques EPISTAR, PICORE, and FAIR, subtraction of two images in which inflowing blood is first tagged and then not tagged yields a qualitative map of perfusion. An important reason this map is not quantitative is that there is a spatially varying delay in the transit of blood from the tagging region to the imaging slice that cannot be measured from ...

متن کامل

A theoretical and experimental comparison of continuous and pulsed arterial spin labeling techniques for quantitative perfusion imaging.

Under ideal conditions, continuous arterial spin labeling (ASL) techniques are higher in SNR than pulsed ASL techniques by a factor of e. Presented here is a direct theoretical and experimental comparison of continuous ASL and pulsed ASL, using versions of both that are amenable to multislice imaging and insensitive to variations in transit times (continuous ASL with a delay before imaging, and...

متن کامل

A general kinetic model for quantitative perfusion imaging with arterial spin labeling.

Recently, several implementations of arterial spin labeling (ASL) techniques have been developed for producing MRI images sensitive to local tissue perfusion. For quantitation of perfusion, both pulsed and continuous labeling methods potentially suffer from a number of systematic errors. In this study, a general kinetic model for the ASL signal is described that can be used to assess these erro...

متن کامل

Assessment of segmental myocardial blood flow and myocardial perfusion reserve by adenosine-stress myocardial arterial spin labeling perfusion imaging.

PURPOSE To determine the feasibility of measuring increases in myocardial blood flow (MBF) and myocardial perfusion reserve (MPR) on a per-segment basis using arterial spin labeled (ASL) magnetic resonance imaging (MRI) with adenosine vasodilator stress in normal human myocardium. MATERIALS AND METHODS Myocardial ASL scans at rest and during adenosine infusion were incorporated into a routine...

متن کامل

Arterial spin labeled MRI detects clinically relevant increases in myocardial blood flow with vasodilatation

OBJECTIVES This study sought to determine whether arterial spin labeled (ASL) cardiac magnetic resonance (CMR) is capable of detecting clinically relevant increases in regional myocardial blood flow (MBF) with vasodilator stress testing in human myocardium. BACKGROUND Measurements of regional myocardial perfusion at rest and during vasodilatation are used to determine perfusion reserve, which...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008