Real-time optical spectrum analysis of a light source using a polarimeter.

نویسندگان

  • X Steve Yao
  • Bo Zhang
  • Xiaojun Chen
  • Alan E Willner
چکیده

Optical spectrum analysis and polarization analysis are not generally related by conventional wisdom. In this paper, we show that the spectrum of a light beam can be obtained using a polarimeter, with a resolution and a speed that cannot be achieved with traditional spectrum analysis methods. We experimentally demonstrate a novel polarimeter-based optical spectrum analyzer (P-OSA) and show that the high-speed and high-resolution nature of the device enables rapid measurement of the spectrum of swept laser sources at a repetition rate of more than 100 kHz. We show the generation of a unique 3-D plot of the spectral shape of a light source as its center wavelength is swept.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A microcomputer automated recording spectropolarimeter

MANY analytical laboratories have available minicomputers or microcomputer systems which routinely find use for data analysis. Recent trends have been toward applying computers not only for computational capabilities, but also for on-line control and data .acquisition from actual analytical instru-mentation. Numerous analytical instruments are being designed to incorporate a computer system as ...

متن کامل

Visible light photocatalytic activity of MWCNT/TiO2 using the degradation of methylene blue

Multi-walled carbon nanotubes (MWCNT)-doped TiO2 thin films were synthesized by the dip-coating method. The obtained products were characterized by SEM, EDX, XRD, and UV-vis absorption spectroscopy. The XRD patterns showed the presence of anatase phase. Absorption spectrum of MWCNT-doped TiO2 revealed a red shift in the optical absorption edge due to carbon doping. The photocatalytic properties...

متن کامل

Real-Time Analysis of Isoprene in Breath by Using Ultraviolet-Absorption Spectroscopy with a Hollow Optical Fiber Gas Cell

A breath analysis system based on ultraviolet-absorption spectroscopy was developed by using a hollow optical fiber as a gas cell for real-time monitoring of isoprene in breath. The hollow optical fiber functions as an ultra-small-volume gas cell with a long path. The measurement sensitivity of the system was evaluated by using nitric-oxide gas as a gas sample. The evaluation result showed that...

متن کامل

Robust estimation of Stokes parameters with a partial liquid-crystal polarimeter under thermal drift.

Polarized light carries information about the various physical parameters that have been acting upon it. Obtaining information on the observed object by studying the polarization of light reflected can be accomplished by several methods. The four Stokes parameters of the reflected light wave (S0, S1, S2, and S3) are generally estimated by observing the scene, with a CCD sensor, through a polari...

متن کامل

Optical Characterization of NIPAM and PAGAT Polymer Gels for Radiation Dosimetry

Introduction The purpose of the current study was to determine optical sensitivity of N-isopropyl acrylamide NIPAM and polyacrylamide gelatin and tetrakis hydroxymethyl phosphoniun chloride (PAGAT) polymer gels for different wavelength of visible light spectrum applied in optical computed tomography method. Materials and Methods NIPAM and PAGAT polymer gels with conventional formulations used f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 16 22  شماره 

صفحات  -

تاریخ انتشار 2008