Finite element analysis of maxillary incisor displacement during en-masse retraction according to orthodontic mini-implant position
نویسندگان
چکیده
OBJECTIVE Orthodontic mini-implants (OMI) generate various horizontal and vertical force vectors and moments according to their insertion positions. This study aimed to help select ideal biomechanics during maxillary incisor retraction by varying the length in the anterior retraction hook (ARH) and OMI position. METHODS Two extraction models were constructed to analyze the three-dimentional finite element: a first premolar extraction model (Model 1, M1) and a residual 1-mm space post-extraction model (Model 2, M2). The OMI position was set at a height of 8 mm from the arch wire between the second maxillary premolar and the first molar (low OMI traction) or at a 12-mm height in the mesial second maxillary premolar (high OMI traction). Retraction force vectors of 200 g from the ARH (-1, +1, +3, and +6 mm) at low or high OMI traction were resolved into X-, Y-, and Z-axis components. RESULTS In M1 (low and high OMI traction) and M2 (low OMI traction), the maxillary incisor tip was extruded, but the apex was intruded, and the occlusal plane was rotated clockwise. Significant intrusion and counter-clockwise rotation in the occlusal plane were observed under high OMI traction and -1 mm ARH in M2. CONCLUSIONS This study observed orthodontic tooth movement according to the OMI position and ARH height, and M2 under high OMI traction with short ARH showed retraction with maxillary incisor intrusion.
منابع مشابه
Lever-arm and mini-implant system for anterior torque control during retraction in lingual orthodontic treatment.
Anterior torque control during retraction is difficult to achieve with lingual orthodontic treatment. This article describes the use of a lever-arm and mini-implant system as absolute anchorage for controlled retraction of the anterior teeth during lingual orthodontic treatment and evaluates 2 protrusion cases treated with this system. Various clinical situations are discussed and analyzed from...
متن کاملMaxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3D finite element study
BACKGROUND Nowadays, mini screws are used in orthodontic tooth movement to obtain maximum or absolute anchorage. They have gained popularity among orthodontists for en masse retraction of anterior teeth after first premolar extraction in maximum anchorage cases. The purpose of this study was to determine the type of anterior tooth movement during the time when force was applied from different m...
متن کاملMini-implant anchorage for en-masse retraction of maxillary anterior teeth: a clinical cephalometric study.
INTRODUCTION This study was conducted to determine the efficiency of mini-implants as intraoral anchorage units for en-masse retraction of the 6 maxillary anterior teeth when the first premolars are extracted compared with conventional methods of anchorage reinforcement. METHODS Thirty patients requiring high anchorage after extraction of the maxillary first premolars were selected for this s...
متن کاملEffects of retraction force and anchorage reinforcement on occlusal force: a model study.
OBJECTIVES The aim of this study was to investigate the effects of retraction force and anchorage reinforcement with orthodontic mini implants on occlusal force. MATERIALS AND METHODS A strain gauge was attached to the palatal surface of the maxillary right first molar on an en masse retraction model. RESULTS Occlusal forces were measured from this model, according to different retraction f...
متن کاملQuantification of intrusive/retraction force and moment generated during en-masse retraction of maxillary anterior teeth using mini-implants: A conceptual approach
OBJECTIVE The aim of the present study was to clarify the biomechanics of en-masse retraction of the upper anterior teeth and attempt to quantify the different forces and moments generated using mini-implants and to calculate the amount of applied force optimal for en-masse intrusion and retraction using mini-implants. METHODS The optimum force required for en-masse intrusion and retraction c...
متن کامل