The Collapse Factor in the Measurement of Venous Pressure Tbe Flow Offluidthroughcollapsibletubes~
ثبت نشده
چکیده
If veins were rigid tubes, then a change in mean right auricular pressure would cause a corresponding change in the peripheral venous pressure, provided the velocity of blood flowing along the veins remained constant. However, veins are not rigid, but collapsible, and it has been shown by Lyon, Kennedy and Burwell (1938), and by Holt (1940), that peripheral venous pressure, referred to the level of the heart as zero, is increased when the vein is above heart level because the veins collapse. Carrier and Rehburg (1923) have also shown that the collapse of peripheral veins and capillaries may maintain capillary pressure at a high level when the capillary is above heartlevel. Since veins are collapsible tubes, and the pressure in the right auricle is generally agreed to be subatmospheric, and there is a small positive tissue space pressure around the veins tending to collapse them, it was thought that changes in mean right auricular pressure might not affect peripheral venous pressure because the veins just before entering the chest might be partially collapsed. METHODSAND RESULTS. When the veins entering the upper end of the thoracic cage were dissected out in the living dog, they were seen to be normally partially collapsed or to dilate and collapse synchronously with respiration. When the animal breathed air which was under a negative pressure the veins were seen to collapse more completely, and when air under a positive pressure was breathed the veins became dilated. The inferior vena cava was seen to collapse, after dissecting the liver away from it, when air under a negative pressure was breathed, but was not seen to collapse with normal respiration. In ten barbitalized dogs with the chest closed, and placed in the supine position, mean peripheral venous pressure was measured in the femoral,
منابع مشابه
The Collapse Factor in the Measurement of Venous Pressure Tbe Flow Offluidthroughcollapsibletubes~
If veins were rigid tubes, then a change in mean right auricular pressure would cause a corresponding change in the peripheral venous pressure, provided the velocity of blood flowing along the veins remained constant. However, veins are not rigid, but collapsible, and it has been shown by Lyon, Kennedy and Burwell (1938), and by Holt (1940), that peripheral venous pressure, referred to the leve...
متن کاملDetermination of Central Venous Pressure from Intraocular Pressure
Background: In many clinical situations, knowledge of central venous pressure (CVP) is important. Measurement of CVP is not always possible. Objective: To determine if intraocular pressure (IOP) can be used as an estimate for CVP. Methods: IOP and CVP were measured concurrently in 30 candidates of coronary artery bypass graft surgery. Those with carotid artery or jugular venous diseases as we...
متن کاملبررسی تأثیر استفاده از چک لیست ثبت اقدامات بر عملکرد پرستاران بخش مراقبت های ویژه در اندازهگیری فشار ورید مرکزی
Background & Aim: The central venous pressure measurement is a common and important care provided by nurses in intensive units. The measurement should be according to the pre-defined standards. The purpose of this study was to evaluate the effect of using a checklist in measuring central venous pressure by nurses . Methods & Materials: This was a nonequivalent group design on 70 nurses w...
متن کاملCorrelation of Ultrasonographic Measurement of Inferior Vena Cava Collapsibility Index with Central Venous Pressure in Diagnosis and Management of Neonatal Shock
Background: Neonatal intensive care unit (NICU)Conventionally, Central Venous Pressure (CVP) monitoring has beenused by intensivists to measure intravascular volume. However, it is an invasive procedure resulting in many complications. Non-invasive ultrasonographic measurement of inferior vena cava collapsibility index (IVC-CI) is a promising alternative. Therefore, this study wasconducte...
متن کاملGas Flow Metering Using the PSO Optimized Interval Type- 2 Fuzzy Neural Network
Orifice flow meter is one of the most common devices in industry which is used for measuring the gas flow. This system includes an orifice plate, temperature and pressure transmitters, and a flow computer. The flow computer is used for collecting information related to temperature, pressure, and their differences under various conditions. Also the flow computer can calculate the flow rate of ga...
متن کامل