Correlation between Corneal Radius of Curvature and Corneal Eccentricity

نویسندگان

  • Patrik Fredin
  • Karthikeyan Baskaran
چکیده

Aim: The primary aim of this study was to find if there is any correlation between the corneal radius of curvature and its eccentricity. Method: 45 subjects participated in this study, 24 emmetropes, 18 myopes and three hyperopes. All subjects were free of ocular abnormalities and had no media opacities. All the subjects had normal ocular health and good visual acuity of 1.0 or better for both distance and near. The values for eccentricity and corneal radius of curvature were obtained by using a Topcon CA-100F Corneal Analyzer. Results: For the 4.5 mm zone the only significant correlation between corneal radius of curvature and eccentricity was obtained for the mean of the meridian (p = 0.007). On the other hand, we found no significant correlation for the average of two meridians or for meridian 1 and meridian 2 separately in the 8.0 mm zone. Conclusions: We found no correlation between the corneal radius of curvature and the eccentricity for both zones. In addition, no correlation could be found between the spherical equivalent of the refractive errors and the corneal eccentricity. The reason for not finding any significant correlation between the two entities could be due to factors such as smaller sample size and poor distribution of refractive errors in the sample. Moreover, there may be other factors that could influence the overall corneal shape like eye shape, axial length and corneal diameter, which was not evaluated in this study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی اثر قطره هوماتروپین 2% بر روی توپوگرافی قرنیه

 ABSTRACT The purpose of this study was the evaluation of cycloplegic effect of homatropine 2% on central corneal curvature and power. 43 volunteers who participated in the study were examined. Thirty-nine of them (28 men and 11 women) which had normal eyes with visual acuity of 20/20 and a mean age of 29.6 ± 6.7 years were selected. Then corneal topography was performed on both eyes. After per...

متن کامل

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

Corneal topography and myopia. A cross-sectional study.

PURPOSE Central corneal curvature is known to vary with refractive error, but the relation between corneal topography and ametropia is less clear. The current study was conducted to determine whether a relation exists between corneal asphericity and myopia. Associations between corneal asphericity and each of the components of refraction also were examined. METHODS Corneal asphericity and api...

متن کامل

Intraocular pressure in a cohort of healthy eastern European schoolchildren: variations in method and corneal thickness

BACKGROUND Intraocular pressure (IOP) in the developing eye of a child is not always easy to measure and there is no technique that is known to be the most accurate for the young eye. Measurements are needed on many cohorts of children with different tonometers to determine how the values correlate between instruments, whether corneal parameters affect readings and whether correlations between ...

متن کامل

Minor influence of myopic laser in situ keratomileusis on the posterior corneal surface.

PURPOSE To check whether myopic LASIK induces changes on the posterior corneal surface. METHODS A Scheimpflug system (Pentacam; Oculus, GmbH, Wetzlar, Germany) was used to measure preoperative and postoperative posterior corneal topography in 27 eyes (of 14 subjects) that had undergone standard myopic LASIK surgery (attempted corrections between -1.25 and -8.50 D) and on 18 nonoperated eyes (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013