Simplified automated method for determination of urinary or serum uric acid, based on reduction of ferric-phenanthroline complex.

نویسندگان

  • J W Nelson
  • K K Batra
چکیده

We describe an automated colorimetric method for determination of uric acid in serum or urine by use of an AutoAnalyzer II or SMA 12/60 (Technicon Corp.). The method depends on reduction of a ferric-phenanthrolirle complex by uric acid under acidic conditions to a ferrous-phenanthroline complex, which absorbs at 505 nm. Advantages of this method over other methods now in use are that color and concentration are linearly related (to 20 mg/100 ml); aqueous reagents are easily prepared, stable, and inexpensive; and interference from ascorbic acid has been eliminated by use of an alkaline copper-containing diluent. The analysis is also free of interference from glucose, creatinine, glutathione, saucylates and hemoglobin. Correlation with results of the Technicon phosphotungstic acid reduction method is excellent (r = .996). Correlation with results of an automated uricase method is satisfactory (r = .979). Recovery of uric acid was 101% over a wide concentration range.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Positive interference of catecholamine metabolites with quantitation of urinary uric acid by the direct acid ferric-reduction method.

We report the effect of major catecholamine metabolites such as homovanillic acid and vanilmandelic acid, normally present in urine, on quantitation of urinary uric acid by the direct acid ferric-reduction procedure [(Am. J. Clin. Pathol. 60, 691 (1973)]. When aqueous uric acid standards containing a mixture of these two metabolites, in concentrations comparable to those in a normal human 24-h ...

متن کامل

An efficient platform based on cupper complex-multiwalled carbon nanotube nanocomposite modified electrode for the determination of uric acid

A new voltammetric sensor for determination of uric acid (UA) by Cuppercomplex- multiwalled carbon nanotube (Cu-complex-CNT) nanocomposite modifiedcarbon paste electrode (CPE) is reported. The electrocatalytic behavior of theCu-complex-CNT nanocomposite modified CPE was studied in pH 2.0 phosphatebuffer solution by chronoamperometry (CA) and cyclic voltammetry (CV) in th...

متن کامل

Evaluation of TRAP and FRAP Methods for Assessing Total Antioxidant Capacity of Rat Serum

Tayefi-Nasrabadi H1, Khodarahmi R2 1. Assistant Professor, Department of Biochemistry, Faculty of Veterinary Medicine, Tabriz University 2. Assistant Professor, Department of Biochemistry, Faculty of Medicine, Kermanshah University of Medical Sciences Abstract Background: Because of the difficulty in measuring each antioxidant component separately and the interactions among different...

متن کامل

Simultaneous determination of dopamine and uric acid using a glassy carbon paste electrode modified with copper- para red complex

A simple approach based on cyclic voltammetry (CV) was developed for the simultaneous determination of dopamine (DA) and uric acid (UA) in the presence of ascorbic acid (AA) using a modified glassy carbon paste electrode (GCPE). In the present study, analytical parameters were optimized and electrochemical performance of modified electrode was investigated. The calibration curves were obtained ...

متن کامل

Micromethod for tocopherol determination in blood serum.

An improved microprocedure for the determination of tocopherol in blood serum is reported. Tocopherol is oxidized by ferric chloride and the pink complex of ferrous ions with 4,7-diphenyl10,10-phenanthroline (bathophenanthroline) is determined spectrophotometrically. The test is more sensitive than colorimetric methods using 2,2’,2” -tripyridine,2,2’-bipyridine (bipyridyl) or 2,4,6tripyridyl-s-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 21 1  شماره 

صفحات  -

تاریخ انتشار 1975