The clinical near gradient stimulus AC/A ratio correlates better with the response CA/C ratio than with the response AC/A ratio.
نویسندگان
چکیده
AIM To provide evidence that a near clinical gradient AC/A ratio could instead reflect the CA/C relationship (the accommodation driven by response to disparity). DESIGN Case control study. METHODOLOGY 27 emmetropic participants with heterophoria <4 PD, 19 with intermittent distance exotropia, and 17 with near exophoria >6 PD were tested. A remote haploscopic photorefractor, which can measure simultaneous convergence and accommodation to a range of targets containing all combinations of presence or absence of binocular disparity, blur, and proximal (looming) cues, was used to assess response AC/A and CA/C relationships. These were compared with clinical gradient AC/A ratios at near and distance fixation using alternate prism cover test and plus or minus lenses. RESULTS Although the near and distance clinical AC/A ratios correlated weakly with each other (p = 0.03), neither clinical method correlated with the more accurate response AC/A ratio from the laboratory method (p = 0.88 and p = 0.93, respectively). The laboratory CA/C ratio correlated strongly with the near clinical AC/A ratio (p = 0.004) but only very weakly with the distance ratio (p = 0.16). CONCLUSIONS The "near gradient AC/A ratio" may actually reflect the CA/C linkage as the dissociation of the prism cover test disrupts vergence accommodation. If the near deviation diverges more with plus lenses, it may be because the lenses allow clear near vision without needing to recruit convergence accommodation to achieve it.
منابع مشابه
Quantifying interactions between accommodation and vergence in a binocularly normal population
Stimulation of the accommodation system results in a response in the vergence system via accommodative vergence cross-link interactions, and stimulation of the vergence system results in an accommodation response via vergence accommodation cross-link interactions. Cross-link interactions are necessary in order to ensure simultaneous responses in the accommodation and vergence systems. The cross...
متن کاملA Novel Dynamic Voltage Regulator with a Multi-level AC/AC Converter
This article proposed a novel topology of dynamic voltage regulator using transformer and PWM multi-level AC/AC converter. In this paper for finding the best value of duty ratio for switches to minimize the THD, the GA algorithm has been used and THD output voltage is assumed to be fitness function. The proposed voltage regulator employs multi-level AC/AC converter to generate compensation volt...
متن کاملChanges in stimulus and response AC/A ratio with vision therapy in Convergence Insufficiency
PURPOSE To evaluate the changes in the stimulus and response Accommodative Convergence to Accommodation (AC/A) ratio following vision therapy (VT) in Convergence Insufficiency (CI). METHODS Stimulus and response AC/A ratio were measured on twenty five CI participants, pre and post 10 sessions of VT. Stimulus AC/A ratio was measured using the gradient method and response AC/A ratio was calcula...
متن کاملEffects of orthoptic treatment on the CA/C and AC/A ratios in convergence insufficiency.
PURPOSE To evaluate the effect of orthoptic treatment on the AC/A (A, accommodation; C, convergence) and CA/C ratios in subjects with convergence insufficiency (CI). METHODS The change in AC/A and CA/C ratios after a 12-week period of home-based orthoptic treatment was examined in 10 subjects (mean age, 25.4+/-4.1 years [SD]). Both the AC/A and CA/C ratios were measured by using gradient resp...
متن کاملEffect of age on the interaction between the AC/A and CA/C ratios.
A number of previous studies have examined the effects of age and the development of presbyopia on either the accommodative convergence to accommodation (AC/A) or convergent accommodation to convergence (CA/C) ratios. However, changes in the interaction of these oculomotor crosslinks with increasing age have received relatively little attention, especially over a wide age distribution. Accordin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Strabismus
دوره 21 2 شماره
صفحات -
تاریخ انتشار 2013