Bacterial aerosol emission rates from municipal wastewater aeration tanks.
نویسندگان
چکیده
In this report we describe the results of a study conducted to determine the rates of bacterial aerosol emission from the surfaces of the aeration tanks of the Metropolitan Water Reclamation District of Greater Chicago John E. Egan Water Reclamation Plant. This study was accomplished by conducting test runs in which Andersen six-stage viable samplers were used to collect bacterial aerosol samples inside a walled tower positioned above an aeration tank liquid surface at the John E. Egan Water Reclamation Plant. The samples were analyzed for standard plate counts (SPC), total coliforms (TC), fecal coliforms, and fecal streptococci. Two methods of calculation were used to estimate the bacterial emission rate. The first method was a conventional stack emission rate calculation method in which the measured air concentration of bacteria was multiplied by the air flow rate emanating from the aeration tanks. The second method was a more empirical method in which an attempt was made to measure all of the bacteria emanating from an isolated area (0.37 m2) of the aeration tank surface over time. The data from six test runs were used to determine bacterial emission rates by both calculation methods. As determined by the conventional calculation method, the average SPC emission rate was 1.61 SPC/m2/s (range, 0.66 to 2.65 SPC/m2/s). As determined by the empirical calculation method, the average SPC emission rate was 2.18 SPC/m2/s (range, 1.25 to 2.66 SPC/m2/s). For TC, the average emission rate was 0.20 TC/m2/s (range, 0.02 to 0.40 TC/m2/s) when the conventional calculation method was used and 0.27 TC/m2/s (range, 0.04 to 0.53 TC/m2/s) when the empirical calculation method was used.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Microbiological Air Pollution in the Surroundings of the Wastewater Treatment Plant with Activated-Sludge Tanks Aerated by Horizontal Rotors
Wastewater treatment plants affect the environment in many different ways. It can be assumed that the intensity and range of microbiological emission is the crucial factor in determining the range of restrictedusage zone. This paper presents emission levels of microbiological pollutants from the wastewater treatment plant in Bartoszyce, Poland. It is a new plant with multifunctional activated-s...
متن کاملComparing the Effects of Deep and Surface Aeration Methods on Density and Type of Airborne Bactria and Fungi in Municipal Wastewater Treatment Plant
Background and purpose: Emission of bioaerosols from wastewater treatment plants is a potential hazard to human health. In this study aimed at investigating the effects of surface and deep aeration techniques on density and type of airborne bacteria and fungi in two municipal wastewater treatment plants. Materials and methods: This descriptive cross-sectional study was done in two wastewater t...
متن کاملEffect of process design and operating parameters on aerobic methane oxidation in municipal WWTPs.
Methane is a potent greenhouse gas and its emission from municipal wastewater treatment plants (WWTPs) should be prevented. One way to do this is to promote the biological conversion of dissolved methane over stripping in aeration tanks. In this study, the well-established Activated Sludge Model n°1 (ASM1) and Benchmark Simulation Model n°1 (BSM1) were extended to study the influence of process...
متن کاملHydrocarbons Emissions from a Municipal Wastewater Treatment Pilot Plant in Vienna
Hydrocarbons emissions were measured from an aeration tank of a municipal wastewater treatment pilot plant. The collected off-gas samples were characterised for C2–C7 hydrocarbons using GC-FID analytical technique while the total volatile organic compounds (TVOC) were measured using a continuous hydrocarbon gas analyser. Approximately, the estimated emission rates for 1 m3 of wastewater from th...
متن کاملAssessment of Seasonal Variation of Microbial Aerosol and Gaseous Emissions from Wastewater Treatment Plant of Morche Khort Industrial Town
Introduction: Wastewater contains a large number of pathogenic and non-pathogenic microorganisms that can become bioaerosols during the treatment processes in different units of the treatment plant, and pose a risk to workers and nearby residents. In this study, the release of bioaerosols from a wastewater treatment plant of Morche Khort Industrial Town was investigated. Materials and Methods:...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied and environmental microbiology
دوره 59 10 شماره
صفحات -
تاریخ انتشار 1993