Retrieval of detached fragment of central venous pressure catheter (CVP) lodged in the right ventricle and pulmonary artery: a case report.

نویسندگان

  • A S Sakijan
  • R Zambahari
  • Z Annuar
  • O Yahya
  • J Ali
چکیده

A successful retrieval of a detached segment of a CVP catheter by percutaneous right transfemoral venous route, using a Dotter intravascular retriever basket, is reported. The procedure was monitored under fluoroscopy. Only local anaesthesia, which was infiltrated around the puncture site, was given to the patient. No significant complication was encountered. Successful retrieval of the detached catheter fragment by percutaneous means obviates the need for thoracotomy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Central Venous Pressure from Intraocular Pressure

Background: In many clinical situations, knowledge of central venous pressure (CVP) is important.  Measurement of CVP is not always possible. Objective: To determine if intraocular pressure (IOP) can be used as an estimate for CVP. Methods: IOP and CVP were measured concurrently in 30 candidates of coronary artery bypass graft surgery.  Those with carotid artery or jugular venous diseases as we...

متن کامل

Perforation of the Right Ventricle Induced by Pulmonary Artery Catheter at Induction of Anesthesia for the Surgery for Liver Transplantation: A Case Report and Reviewed of Literature

We report a case of a 45-year-old male patient diagnosed with liver cirrhosis by hepatitis C and alcohol, with a Child-Pugh score C and a model for end-stage liver disease (MELD) score of 27, and submitted to liver transplantation. The subject underwent insertion of the pulmonary artery catheter (PAC) in the right internal jugular vein, with technical difficulty concerning catheter advance. The...

متن کامل

Pulmonary atresia with ventricular septal defect: a case for central venous pressure and oxygen saturation monitoring.

A 21-year-old patient with pulmonary atresia and ventricular septal defect (PA-VSD) was admitted to the hospital for tubal ligation. Invasive arterial and central venous (CVP) pressure, pulse oximetric oxygen saturation (SpO2), and (from the tip of oximetric central venous catheter) central venous oxygen saturation (ScvO2) and oxygen extraction rate (ExO2) were continuously monitored. Heart rat...

متن کامل

Management of Catheter Induced Upper Limb Suppurative Thrombophlebitis in a Patient after Coronary Artery Bypass Graft Surgery: a Case Report

Introduction: One of the important complications of peripheral venous catheters is suppurative thrombophlebitis that would be life threatening without treatment. In this report, we introduce a patient who developed purulent thrombophlebitis due to venous catheter in the upper limb after coronary artery bypass graft surgery. Multiple abscess formation was developed on her upper limb after the th...

متن کامل

A Case of Unrecognized Intrathoracic Placement of a Subclavian Central Venous Catheter in a Patient with Large Traumatic Hemothorax

Traditional recommendations suggest placement of a subclavian central venous catheter (CVC) ipsilateral to a known pneumothorax to minimize risk of bilateral pneumothorax. We present the case of a 65-year-old male with a right hemopneumothorax who was found to have intrathoracic placement of his right subclavian CVC at thoracotomy despite successful aspiration of blood and transduction of centr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Medical journal of Malaysia

دوره 45 4  شماره 

صفحات  -