FAULT MANAGEMENT IN ELECTRICAL DISTRIBUTION SYSTEMS Final report of the CIRED Working Group WG03 Fault Management FOREWORD
نویسنده
چکیده
Dr. Matti Lehtonen, VTT Energy, Finland (convenor) Dr. Damian Cortinas, Electricité de France, (secretary) Mr. Rino Anelli, ENEL, Italy Mr. Jean-Paul Krivine, Electricité de France Mr. Iñaki Ojanguren, Iberdrola, Spain Mr. Philippe Perusset, Electricité Neuchâteloise, Switzerland Prof. Peter Schegner, TU Dresden, germany Mr. Philip Tempelaere, Electrabel, Belgium Dr. Walter Tenschert, OKA, Austria Mr. Antonio Gomes Varela, Electricidade de Lisboa, Portugal
منابع مشابه
Influence of Fault Current Limiter in Voltage Drop and TRV Considering Wind Farm
Influence of distributed generation systems in the distribution systems can increase the level of short-circuit current. The effectiveness of distributed generation systems is affected by the size, location, type of distributed generation systems technology, and the methods of connecting to distribution systems. Wind turbine system is the examples of distributed generation source. Not only does...
متن کاملAn Unknown Input Observer for Fault Detection Based on Sliding Mode Observer in Electrical Steering Assist Systems
Steering assist system controls the force transfer behavior of the steering system and improves the steering probability of the vehicle. Moreover, it is an interface between the diver and vehicle. Fault detection in electrical assisted steering systems is a challenging problem due to frequently use of these systems. This paper addresses the fault detection and reconstruction in automotive elect...
متن کاملModelling and Simulation of a Transformer With Inter-turn Fault Including Saturation Effect and Variable Fault Parameters
This investigation deals with a mathematical model for a distribution transformer including saturation effect. To this end, the equations related to a three phase transformer are specified and the effect of an inter-turn fault is included. Naturally by applying an inter-turn fault the inductance and resistance matrix will change. Thus, unknown quantities of inductances and resistances for compl...
متن کاملThe Impact of Superconducting Fault Current Limiter Locations on Voltage Sag in Power Distribution System
In this paper, the impacts of installing superconducting fault current limiter (SFCL)in radial and loop power distribution system are evaluated to improve voltage sag in both cases of with and without distributed generations (DG). Among various SFCLs, the hybrid type with a superconducting element in parallel with a current limiting reactor (CLR) is selected. This is more effective than resisto...
متن کاملOptimal DG Allocation and Thyristor-FCL Controlled Impedance Sizing for Smart Distribution Systems Using Genetic Algorithm
Recently, smart grids have been considered as one of the vital elements in upgrading current power systems to a system with more reliability and efficiency. Distributed generation is necessary for most of these new networks. Indeed, in all cases that DGs are used in distribution systems, protection coordination failures may occur in multiple configurations of smart grids using DGs. In different...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1999