MRI-related heating near deep brain stimulation electrodes: more data are needed.
نویسندگان
چکیده
Magnetic resonance imaging (MRI) of patients with implanted deep brain stimulation (DBS) devices poses a challenge for healthcare providers. As a consequence of safety concerns about magnetic field interactions with the device, induced electrical currents and thermal damage due to radiofrequency heating, a number of stringent guidelines have been proposed by the device manufacturer. Very few detailed investigations of these safety issues have been published to date, and the stringent manufacturer guidelines have gone unchallenged, leading some hospitals and imaging centers around the world to ban or restrict the use of MRI in DBS patients. The purpose of this review is to stimulate research towards defining appropriate guidelines for the use of MRI in patients with DBS. Additionally, this review is intended to help healthcare providers and researchers make sound clinical judgments about the use of MRI in the setting of implanted DBS devices.
منابع مشابه
Pathological Alterations and Stress Responses near DBS Electrodes after MRI Scans at 7.0T, 3.0T and 1.5T: An In Vivo Comparative Study
OBJECTIVE The purpose of this study was to investigate the pathological alterations and the stress responses around deep brain stimulation (DBS) electrodes after magnetic resonance imaging (MRI) scans at 7.0T, 3.0T and 1.5T. MATERIALS AND METHODS DBS devices were stereotactically implanted into the brains of New Zealand rabbits, targeting the left nucleus ventralis posterior thalami, while on...
متن کاملBilateral neurostimulation systems used for deep brain stimulation: in vitro study of MRI-related heating at 1.5 T and implications for clinical imaging of the brain.
Deep brain stimulation (DBS) is used increasingly in the field of movement disorders. The implanted electrodes create not only a prior risk to patient safety during MRI, but also a unique opportunity in the collection of functional MRI data conditioned by direct neural stimulation. We evaluated MRI-related heating for bilateral neurostimulation systems used for DBS with an emphasis on assessing...
متن کاملLow Power MRI Techniques for Neurosurgical Planning and Post-surgical Assessment of Deep Brain Stimulators in Patients with Medically Refractory Parkinson’s Disease or Dystonia
Medically refractory Parkinson's or dystonia conditions are often treated with deep brain stimulation (DBS) that are managed with the help of very restricted MRI due to safety concerns. The resulting MR images are often suboptimal but are still considered valuableto assess post-surgical complications as well as electrode placement accuracy. Absorbed radiofrequency power near the DBS electrodes ...
متن کاملHeating induced near deep brain stimulation lead electrodes during magnetic resonance imaging with a 3 T transceive volume head coil.
Heating induced near deep brain stimulation (DBS) lead electrodes during magnetic resonance imaging with a 3 T transceive head coil was measured, modeled, and imaged in three cadaveric porcine heads (mean body weight = 85.47 ± 3.19 kg, mean head weight = 5.78 ± 0.32 kg). The effect of the placement of the extra-cranial portion of the DBS lead on the heating was investigated by looping the extra...
متن کاملRelationship of the P Angle with Stereotactic Arc in Intraoperative Outcome of Patients with Parkinson’s Disease Undergoing Deep Brain Stimulation
Background & Aim: DBS (deep brain stimulation) is a new and successful technique in treatment of symptoms of Parkinsonism especially after drug resistance. Research in this field is mostly designed for evolution of this technique. The present study aimed at evaluating the relationship between the angle formed in midsagittal and STN (sub-thalamic nucleus) axis line and recording l...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Stereotactic and functional neurosurgery
دوره 89 3 شماره
صفحات -
تاریخ انتشار 2011