Abstract Submitted for the MAR07 Meeting of The American Physical Society Confounding Effect of Spot-Size on the Wavelength-Dependence of Tissue Ablation Metrics1 M. SHANE HUTSON, GILMA ADUNAS, YAOWU

نویسنده

  • Shane Hutson
چکیده

Submitted for the MAR07 Meeting of The American Physical Society Confounding Effect of Spot-Size on the Wavelength-Dependence of Tissue Ablation Metrics1 M. SHANE HUTSON, GILMA ADUNAS, YAOWU XIAO, Vanderbilt University — Tunable free-electron lasers have been used in several previous studies to investigate the mid-IR wavelength-dependence of tissue ablation. These studies gave conflicting results on an important question: do the ablation metrics depend on targeting the laser energy to a water or protein vibration? Here, we investigate the effects of two parameters that varied widely in previous studies – fluence and focused spot-size. We measured ablation threshold, etch depth and collateral damage in porcine corneas for a set of five matched wavelengths – same absorption coefficients, but different primary chromophores. Although the ablation thresholds are similar, the slope of etch depth versus fluence (ablation efficiency) differs by up to a factor of five. These differences are most strongly dependent on the focused spot diameter, not wavelength. When spot sizes are matched, proteintargeting wavelengths still leave less collateral damage, but they remove tissue less efficiently. The confounding roles of fluence and spot size have strong implications for the interpretation of previous wavelength-dependent results. 1Supported by grant FA9550-04-1-0045 from the DoD MFEL Program. M. Shane Hutson Vanderbilt University Date submitted: 21 Nov 2006 Electronic form version 1.4

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interplay of wavelength, fluence and spot-size in free-electron laser ablation of cornea.

Infrared free-electron lasers ablate tissue with high efficiency and low collateral damage when tuned to the 6-microm range. This wavelength-dependence has been hypothesized to arise from a multi-step process following differential absorption by tissue water and proteins. Here, we test this hypothesis at wavelengths for which cornea has matching overall absorption, but drastically different dif...

متن کامل

Abstract Submitted for the MAR07 Meeting of The American Physical Society Effect of Orientation in Translocation of Polymers through Nanopores

Submitted for the MAR07 Meeting of The American Physical Society Effect of Orientation in Translocation of Polymers through Nanopores STANISLAV KOTSEV, ANATOLY KOLOMEISKY, Rice University — The motion of a polymer with inhomogeneous structure through a nanopore is discussed theoretically. Specifically, we consider the translocation of polymer consisting of one double-stranded and one single-str...

متن کامل

Wavelength-dependent conformational changes in collagen after mid-infrared laser ablation of cornea.

We ablated porcine corneas with a free electron laser tuned to either 2.77 or 6.45 microm, two matched wavelengths that predominantly target water and protein, respectively. The ejected nonvolatile debris and the crater left behind were examined by circular dichroism, Raman spectroscopy, and scanning electron microscopy to characterize the postablation conformation of collagen proteins. We foun...

متن کامل

Wavelength-dependent collagen fragmentation during mid-IR laser ablation.

Mid-infrared free-electron lasers have proven adept in surgical applications. When tuned to wavelengths between 6 and 7 microm, such lasers remove defined volumes of soft tissue with very little collateral damage. Previous attempts to explain the wavelength-dependence of collateral damage have invoked a wavelength-dependent loss of protein structural integrity. However, the molecular nature of ...

متن کامل

Abstract Submitted for the MAR07 Meeting of The American Physical Society Degenerate four-wave mixing with defocusing nonlinearity JASON FLEISCHER,

Submitted for the MAR07 Meeting of The American Physical Society Degenerate four-wave mixing with defocusing nonlinearity JASON FLEISCHER, WENJIE WAN, SHU JIA, Princeton University — We experimentally demonstrate four-wave mixing (FWM) effects in a defocusing nonlinear photorefractive medium, in both one and two dimensions. By using a rectangular crystal, we observe the nonlinear generation of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012