Near infrared spectroscopy (NIRS) distinguishes seizure types
نویسندگان
چکیده
Near infrared spectroscopy (NIRS) is a noninvasive method for bedside measurement of cerebral oxygenation (SaO(2)). The purpose of this study was to establish differences in SaO(2)for complex partial seizures (CPS) and rapidly secondarily generalized CPS (RCPS). We studied eight adults with medically refractory epilepsy undergoing evaluation for temporal lobectomy. We continually measured cerebral SaO(2)via a Somanetic Invos 3100a cerebral oximeter, pre-ictal (5 minutes), ictal, immediate (30 seconds) post-ictal, and late post-ictal (5 minutes after ictus). Seventeen seizures (12 CPS, four RCPS and one subclinical) were recorded in eight patients. The percentage change in cerebral SaO(2)from pre-ictal to ictal periods was derived. Cerebral SaO(2)increased (percentage change, mean: 16.6, SD: 13.9) for CPS and decreased (percentage change, mean: 51.1, SD: 18.1) for RCPS. No change in cerebral oximetry was recorded for the subclinical seizure. Post-ictal (immediate and late) increase in cerebral SaO(2)was seen for 11 of the 17 seizures (nine CPS and two RCPS). Peripheral SaO(2)rose greater than 93% for all CPS and the subclinical seizure, but decreased between 78 and 84% during RCPS. These results suggest NIRS distinguishes cerebral SaO(2)patterns between CPS and RCPS. The decrease in peripheral SaO(2), however, may account for the decrease in cerebral SaO(2)seen in generalized seizures.
منابع مشابه
Exploring the capability of wireless near infrared spectroscopy as a portable seizure detection device for epilepsy patients
PURPOSE Near infrared spectroscopy (NIRS) has proved useful in measuring significant hemodynamic changes in the brain during epileptic seizures. The advance of NIRS-technology into wireless and portable devices raises the possibility of using the NIRS-technology for portable seizure detection. METHODS This study used NIRS to measure changes in oxygenated (HbO), deoxygenated (HbR), and total h...
متن کاملPotential of Near-Infrared Reflectance Spectroscopy (NIRS) to Predict Nutrient Composition of Bromus tomentellus
Determination of forage quality of available species is one of the fundamentalfactors for the management of rangelands. Near-Infrared Reflectance Spectroscopy (NIRS)was used to analysis the Nitrogen (N), Acid Detergent Fiber (ADF), Dry MatterDigestibility (DMD) and Metabolizable Energy (ME) content of three phenological stages(vegetative, flowering and seeding) of Bromus tomentellus samples in ...
متن کاملNon-invasive pre-surgical investigation of a 10 year-old epileptic boy using simultaneous EEG–NIRS
Near-infrared spectroscopy (NIRS) is a novel imaging technique of potential value in the pre-surgical investigation of patients with refractory epilepsy. We recorded simultaneously electrophysiology (EEG; Compumedics, USA) and near-infrared spectroscopy (NIRS; ISS, USA) to examine the localization of the ictal onset zone and assess language lateralization in a young epileptic boy (L.H., 10 year...
متن کاملEstimating Nitrogen and Acid Detergent Fiber Contents of Grass Species using Near Infrared Reflectance Spectroscopy (NIRS)
Chemical assessments of forage clearly determine the forage quality; however, traditional methods of analysis are somehow time consuming, costly, and technically demanding. Near Infrared Reflectance Spectroscopy (NIRS) has been reported as a method for evaluating chemical composition of agriculture products, food, and forage and has several advantages over chemical analyses such as conducting c...
متن کاملDetermination of Protein and Moisture in Fishmeal by Near-Infrared Reflectance Spectroscopy and Multivariate Regression Based on Partial Least Squares
The potential of Near Infrared Reflectance Spectroscopy (NIRS) as a fast method to predict the Crude Protein (CP) and Moisture (M) content in fishmeal by scanning spectra between 1000 and 2500 nm using multivariate regression technique based on Partial Least Squares (PLS) was evaluated. The coefficient of determination in calibration (R2C) and Standard Error of Calibra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Seizure
دوره 9 شماره
صفحات -
تاریخ انتشار 2000