Cutting balloon versus conventional balloon angioplasty for the treatment of in-stent restenosis: results of the restenosis cutting balloon evaluation trial (RESCUT).

نویسندگان

  • Remo Albiero
  • Sigmund Silber
  • Carlo Di Mario
  • Carmelo Cernigliaro
  • Salvatore Battaglia
  • Bernhard Reimers
  • Arian Frasheri
  • Volker Klauss
  • Joseph M Auge
  • Paolo Rubartelli
  • Marie-Claude Morice
  • Alberto Cremonesi
  • Joachim Schofer
  • Alessandro Bortone
  • Antonio Colombo
چکیده

OBJECTIVES The aim of this trial was to compare cutting balloon angioplasty (CBA) with conventional balloon angioplasty (i.e., percutaneous transluminal coronary angioplasty [PTCA]) for the treatment of patients with coronary in-stent restenosis (ISR). BACKGROUND Retrospective studies suggest CBA might be superior to conventional PTCA in the treatment of ISR. METHODS The Restenosis Cutting Balloon Evaluation Trial (RESCUT) is a multicenter, randomized, prospective European trial including 428 patients with all types of ISR (e.g., focal, multifocal, diffuse, proliferative). RESULTS In both groups, the majority of ISR lesions were shorter than 20 mm. The length of restenotic stents was similar (CBA: 18.6 +/- 9.7 mm; PTCA: 18.3 +/- 8.7 mm). The number of balloons used to treat ISR was lower in the CBA group: only one balloon was used in 82.3% of CBA cases, compared with 75% of PTCA procedures (p = 0.03). Balloon slippage was less frequent in the CBA group (CBA 6.5%, PTCA 25%; p < 0.01). There was a trend toward a lower need for additional stenting in the CBA group (CBA 3.9%, PTCA 8.0%; p = 0.07). At seven-month angiographic follow-up, the binary restenosis rate was not different between the groups (CBA 29.8%, PTCA 31.4%; p = 0.82), with a similar pattern of recurrent restenosis. Clinical events at seven months were also similar. CONCLUSIONS Cutting balloon angioplasty did not reduce recurrent ISR and major adverse cardiac events, as compared with conventional PTCA. However, CBA was associated with some procedural advantages, such as use of fewer balloons, less requirement for additional stenting, and a lower incidence of balloon slippage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cutting Balloon Angioplasty versus Conventional Balloon Angioplasty for In-Stent Restenosis Treated by Intracoronary Radiation Therapy

Background: Cutting Balloon angioplasty (CBA) may be a useful treatment modality for in-stent restenosis (ISR) as it maintains a stable position during dilatation and results in potentially less injury than plain old balloon angioplasty (POBA). The purpose of this study was to compare CBA and POBA with intracoronary radiation therapy (IRT) for in-stent restenosis (ISR). Methods: We selected 157...

متن کامل

Cutting balloon combined with paclitaxel-eluting balloon for treatment of in-stent restenosis.

BACKGROUND The optimal therapy for in-stent restenosis (ISR) is controversial. We evaluated three different strategies for the treatment of in-stent restenosis: cutting balloon angioplasty (CBA), paclitaxel-eluting balloon angioplasty (PEBA) and cutting balloon followed by paclitaxel-eluting balloon angioplasty (CB+PEBA). METHODS Forty-five coronary arteries in 45 mini-pigs underwent oversize...

متن کامل

Cutting balloon angioplasty for intrastent restenosis treatment.

We describe here two patients with angiographic diagnosis of intrastent restenosis and regional myocardial ischemia. One stent restenosis was located in a native coronary artery and the other in a vein graft. Both were treated with cutting balloon angioplasty (CBA), inflated at low pressures. Angiographic success was obtained and both patients were discharged in the day after the procedure. Cut...

متن کامل

A Rare and Serious Unforeseen Complication of Cutting Balloon Angioplasty

Cutting balloon angioplasty (CBA) is one of the adept ways of treating "in-stent restenosis." Various complications related to cutting balloon angioplasty have been reported including arterial rupture, delayed perforation and fracture of microsurgical blades. Here we report a very unusual and inadvertent extraction of a stent previously deployed in the ramus intermedius coronary branch by a cut...

متن کامل

Lower expression of neutrophil adhesion molecule indicates less vessel wall injury and might explain lower restenosis rate after cutting balloon angioplasty.

BACKGROUND The Cutting Balloon is a novel dilatation catheter for coronary angioplasty (InterVentional Technologies Inc). It produces longitudinal, microsurgical incisions in the vessel wall before the actual dilatation. It is assumed that these controlled surgical incisions relieve hoop stress and reduce vessel wall injury and eventually restenosis. However, no clinical indicator to support th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 43 6  شماره 

صفحات  -

تاریخ انتشار 2004