Comparison of the diagnostic ability of blue laser imaging magnification versus pit pattern analysis for colorectal polyps

نویسندگان

  • Arihiro Nakano
  • Yoshiki Hirooka
  • Takeshi Yamamura
  • Osamu Watanabe
  • Masanao Nakamura
  • Kohei Funasaka
  • Eizaburo Ohno
  • Hiroki Kawashima
  • Ryoji Miyahara
  • Hidemi Goto
چکیده

Background and study aims There have been few evaluations of the diagnostic ability of new narrow band light observation blue laser imaging (BLI). The present prospective study compared the diagnostic ability of BLI magnification and pit pattern analysis for colorectal polyps. Patients and methods We collected lesions prospectively, and the analysis of images was made by two endoscopists, retrospectively. A total of 799 colorectal polyps were examined by BLI magnification and pit pattern analysis at Nagoya University Hospital. The Hiroshima narrow-band imaging classification was used for BLI. Differentiation of neoplastic from non-neoplastic lesions and diagnosis of deeply invasive submucosal cancer (dSM) were compared between BLI magnification and pit pattern analysis. Type C2 in the Hiroshima classification was evaluated separately, because application of this category as an index of the depth of cancer invasion was considered difficult. Results We analyzed 748 colorectal polyps, excluding 51 polyps that were inflammatory polyps, sessile serrated adenoma/polyps, serrated adenomas, advanced colorectal cancers, or other lesions. The accuracy of differential diagnosis between neoplastic and non-neoplastic lesions was 98.4 % using BLI magnification and 98.7 % with pit pattern analysis. In addition, the diagnostic accuracy of BLI magnification and pit pattern analysis for dSM for cancer was 89.5 % and 92.1 %, respectively. When type C2 lesions were excluded, the diagnostic accuracy of BLI for dSM was 95.9 %. The 18 type C2 lesions comprised 1 adenoma, 9 intramucosal or slightly invasive submucosal cancers, and 8 dSM. Pit pattern analysis allowed accurate diagnosis of the depth of invasion in 13 lesions (72.2 %). Conclusions Most colorectal polyps could be diagnosed accurately by BLI magnification without pit pattern analysis, but we should add pit pattern analysis for type C2 lesions in the Hiroshima classification.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic accuracy of narrow-band imaging and pit pattern analysis significantly improved for less-experienced endoscopists after an expanded training program.

BACKGROUND Previous reports assessing diagnostic skill using narrow-band imaging (NBI) and pit pattern analysis for colorectal polyps involved only highly experienced endoscopists. OBJECTIVE To evaluate diagnostic skills of less-experienced endoscopists (LEE group) for differentiation of diminutive colorectal polyps by using NBI and pit pattern analysis with and without magnification after an...

متن کامل

Differential diagnosis of colorectal polyps with narrow band imaging colonoscopy without magnification.

BACKGROUND/AIMS Narrow band imaging (NBI) endoscopy can be used for gross differentiation between the types of colonic polyps. This study was conducted as a retrospective study for estimation of the interobserver and intra-observer agreement of the pit pattern of the mucosal surface and the accuracy of histology prediction. METHODS A total of 159 patients underwent complete colonoscopy and 21...

متن کامل

Correlation of Narrow Band Imaging with Magnifying Colonoscopy and Histology in Colorectal Tumors

BACKGROUND/AIMS Narrow band imaging (NBI) is a new technique that uses optical filters for imaging of mucosal morphology. The aim of this study was to correlate findings of NBI with magnifying colonoscopy and histology for prediction of neoplastic colorectal lesion. METHODS Between September 2005 and December 2007, 107 colon polyps from 68 patients were detected by conventional colonoscopy an...

متن کامل

Digital Chromoendoscopy for Diagnosis of Diminutive Colorectal Lesions

Introduction. To compare the accuracy of digital and real-time chromoendoscopy for the differential diagnosis of diminutive (<5 mm) neoplastic and nonneoplastic colorectal lesions. Materials and Methods. This is a prospective randomized study comparing the Fujinon intelligent color enhancement (FICE) system (65 patients/95 lesions) and indigo carmine (69 patients/120 lesions) in the analysis of...

متن کامل

Pit pattern analysis by magnifying chromoendoscopy for the diagnosis of colorectal polyps.

BACKGROUND AND PURPOSE The development of magnifying chromoendoscopy has facilitated the observation of mucosal pit patterns. This study investigated the value of this technology in predicting the histologic findings of colorectal lesions. METHODS A total of 954 colorectal polyps were included. After identifying the lesions at colonoscopy, 0.2% indigocarmine solution was sprayed and then the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2017