Rapid diagnosis and management of thoracic aortic dissection and intramural haematoma: a prospective study of advantages of multiplane vs. biplane transoesophageal echocardiography.

نویسندگان

  • M Pepi
  • J Campodonico
  • C Galli
  • G Tamborini
  • P Barbier
  • E Doria
  • A Maltagliati
  • M Alimento
  • R Spirito
چکیده

AIMS The purposes of this study were to compare the accuracy of multiplane vs. biplane transoesophageal echocardiography (TEE) in the diagnosis of aortic dissection and aortic intramural haematoma, and to test whether these techniques provide all the diagnostic information required to make management decisions. METHODS AND RESULTS Fifty-eight consecutive patients with clinically suspected aortic dissection were studied with multiplane TEE; all cases who required surgery underwent intraoperative monitoring with multiplane TEE. The following multiplane TEE data were analysed: the angle between current and 0 degrees plane at which each view was obtained; the success rate in the evaluation of true and false lumen, entry tear, coronary artery involvement, aortic regurgitation, pericardial effusion. Advantages of multiplane over biplane TEE have been evaluated by the demonstration of usefulness of views obtained in planes other than 0 degrees-20 degrees or 70 degrees-110 degrees, assuming that with manipulation of a biplane probe a 20 degrees arc could be added to the conventional horizontal and vertical planes. On the basis of TEE findings, aortic dissection was confirmed in 36 cases (18 type A, 12 type B, six intramural haematoma). The specificity and sensitivity of TEE in terms of the presence or absence of aortic dissection or intramural haematoma were 100%. An additional clinical value of multiplane over biplane TEE in the evaluation of ascending aorta, aortic arch, entry tears and coronary artery involvement was demonstrated. All cases with type A aortic dissection or intramural haematoma involving the ascending aorta had an operation that was performed immediately after the diagnosis (hospital mortality, 13%). Patients with type B aortic dissection were treated medically; 25% of these cases were operated later (hospital mortality, 0%). CONCLUSIONS Multiplane and biplane TEE have excellent and similar accuracies in the evaluation of aortic dissection and intramural haematoma. Multiplane TEE improves the visualization of coronary arteries, aortic arch and entry tears; it appears to be an ideal method as the sole diagnostic approach before surgery in type A aortic dissection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Role of transoesophageal echocardiography in the diagnosis and management of aortic root abscess.

OBJECTIVE To assess and compare the roles of transthoracic and transoesophageal echocardiography in the diagnosis and management of an aortic root abscess. DESIGN To select patients with echocardiographic diagnosis of aortic valve endocarditis with and without an aortic root abscess and correlate this with a retrospective review of surgical and necropsy data. SETTING Tertiary referral centr...

متن کامل

MINI-SYMPOSIUM Diagnosis of aortic intramural haematoma

A ortic intramural haematoma (IMH), a variant form of classic aortic dissection, has been accepted as an increasingly recognised and potentially fatal entity of acute aortic syndrome (AAS). In classic aortic dissection, flow communication occurs through a demonstrable primary intimal tear and blood flow propagation creates a so called ‘‘double channel aorta’’ with a true and false lumen. In IMH...

متن کامل

Diagnosis of aortic intramural haematoma.

A ortic intramural haematoma (IMH), a variant form of classic aortic dissection, has been accepted as an increasingly recognised and potentially fatal entity of acute aortic syndrome (AAS). In classic aortic dissection, flow communication occurs through a demonstrable primary intimal tear and blood flow propagation creates a so called ‘‘double channel aorta’’ with a true and false lumen. In IMH...

متن کامل

Task Force Report Diagnosis and management of aortic dissection* Recommendations of the Task Force on Aortic Dissection, European Society of Cardiology†

Page Preamble ..................................................................1642 Introduction.............................................................1643 Aortic wall disease...................................................1643 Inherited disease ..................................................1643 Aortic disease in infancy and childhood .............1645 Ageing of the aorta............

متن کامل

Echocardiography in the emergency assessment of acute aortic syndromes.

Acute aortic syndrome (AAS) is a collective term for several life-threatening acute aortic conditions: aortic dissection, intramural haematoma (IMH), penetrating atherosclerotic ulcer, and traumatic transection. Mortality from acute ascending aortic (type A) dissection increases rapidly immediately after presentation, reaching 1-2% per hour for the first 48 h. Early surgical intervention is rec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology

دوره 1 1  شماره 

صفحات  -

تاریخ انتشار 2000