Selecting Detectors for Compounds with No Optical Absorbance
ثبت نشده
چکیده
In HPLC, the detector is selected in accordance with the analyte. Many of the detectors used are based on optical absorbance, such as UV-Vis absorbance detectors and photodiode array (PDA) detectors. Absorbance detectors have the following features: The detector sensitivity and selectivity can be adjusted by setting an appropriate detector wavelength. The sensitivity is relatively high (although it depends on the molar extinction coefficient). The relationship between the elution concentration and the detection response is linear and covers a wide range (Lambert-Beer law). The gradient elution method can be used. The stability is high. The difference between instruments is small. They perform nondestructive detection and can therefore be used for fractionation. It is partly because of this large number of features and the consequent high level of versatility that absorbance detectors are used so widely.
منابع مشابه
Optical Characterization of NIPAM and PAGAT Polymer Gels for Radiation Dosimetry
Introduction The purpose of the current study was to determine optical sensitivity of N-isopropyl acrylamide NIPAM and polyacrylamide gelatin and tetrakis hydroxymethyl phosphoniun chloride (PAGAT) polymer gels for different wavelength of visible light spectrum applied in optical computed tomography method. Materials and Methods NIPAM and PAGAT polymer gels with conventional formulations used f...
متن کاملUltraviolet detectors based on annealed zinc oxide thin films: epitaxial growth and physical characterizations
In this report, ultraviolet (UV) detectors were fabricated based on zinc oxide thin films. The epitaxial growth of zinc oxide thin films was carried out on bare glass substrate with preferred orientation to (002) plane of wurtzite structure through radio frequency sputtering technique. The structural properties indicated a dominant peak at 2θ=34.28º which was matched with JCPDS reference card N...
متن کاملOptical errors in a liquid chromatography absorbance cell.
The shadowgraph method is used to visualize mobile phase flow through a liquid chromatography absorbance cell with "Z" flow geometry. It is shown that mixing is incomplete in the cell. Composition gradients persist throughout the elution of any sample. The gradients systematically change as the sample flows through the cell. Additionally, window wedge angles are measured in several cells. The i...
متن کاملImproving 3-D Imaging Breast Cancer Diagnosis Systems Using a New Method for Placement of Near-Infrared Sources and Detectors
The objective of this research was to improve 3-D imaging system by near-infrared light emission in breast tissue to achieve a more accurate diagnosis of tumor. The results of repeated experiments in this research have shown that with this imaging system, a more accurate diagnosis of abnormal area depends on the location of the sources and detectors. Therefore, an optimal location model has bee...
متن کاملDevelopment of a Novel Optical Biosensor for Detection of Organophoshorus Pesticides Based on Methyl Parathion Hydrolase Immobilized by Metal-Chelate Affinity
We have developed a novel optical biosensor device using recombinant methyl parathion hydrolase (MPH) enzyme immobilized on agarose by metal-chelate affinity to detect organophosphorus (OP) compounds with a nitrophenyl group. The biosensor principle is based on the optical measurement of the product of OP catalysis by MPH (p-nitrophenol). Briefly, MPH containing six sequential histidines (6 × H...
متن کامل