In vivo testing of a novel blood pump for short-term extracorporeal life support.
نویسندگان
چکیده
BACKGROUND Centrifugal pumps are used increasingly for temporary mechanical support for the treatment of cardiogenic shock. However, centrifugal pumps can generate excessive negative pressure and are afterload sensitive. A previously developed modified roller pump mitigates these limitations both in vitro and in preliminary animal experiments. We report the results of intermediate-term testing of our evolving pump technology, known as the BioVAD. METHODS The BioVAD was implanted in 6 adult male sheep (62.5±3.9 kg), with drainage from the left atrium and reinfusion into the descending aorta. The sheep were monitored for 5 days. Heparin was given during the initial implantation, but no additional anticoagulants were given. Data collected included hemodynamic status, pump flow and pressures, laboratory values to monitor end-organ function and hemolysis, pathologic specimens to evaluate for thromboembolic events and organ ischemia, and explanted pump evaluation results. RESULTS All animals survived the planned experimental duration and there were no pump malfunctions. Mean BioVAD flow was 3.57±0.30 L/min (57.1 mL/kg/min) and mean inlet pressure was -30.51±4.25 mm Hg. Laboratory values, including plasma free hemoglobin, creatinine, lactate, and bilirubin levels, remained normal. Three animals had small renal cortical infarcts, but there were no additional thromboembolic events or other abnormalities seen on pathologic examination. No thrombus was identified in the BioVAD blood flow path. CONCLUSIONS The BioVAD performed well for 5 days in this animal model of temporary left ventricular assistance. Its potential advantages over centrifugal pumps may make it applicable for short-term mechanical circulatory support.
منابع مشابه
The cost impact of short-term ventricular assist devices and extracorporeal life support systems therapies on the National Health Service in the UK.
OBJECTIVES The objective of the study was to assess the cost of using different blood pumps for short-term ventricular assist device (VAD) and extracorporeal life support (ECLS) systems for cardiac and cardiorespiratory failure in the UK. METHODS The cost analysis presented was based on evaluation of the time required to provide circulatory support for the following indications: post-cardiac ...
متن کاملIn vivo anticoagulant properties of a novel nucleotide-based thrombin inhibitor and demonstration of regional anticoagulation in extracorporeal circuits.
Using a novel in vitro selection/amplification technique, we have recently identified a new class of thrombin inhibitors based on single-stranded DNA oligonucleotides. One oligonucleotide, GGTTGGTGTGGTTGG (thrombin, aptamer), showed potent anticoagulant activity in vitro. We have initiated pharmacologic studies in cynomolgus monkeys to study the thrombin aptamer's in vivo anticoagulant properti...
متن کاملUsing Daily Plasma-Free Hemoglobin Levels for Diagnosis of Critical Pump Thrombus in Patients Undergoing ECMO or VAD Support.
Patients supported with extracorporeal membrane oxygenation (ECMO) or short-term centrifugal ventricular assist devices (VADs) are at risk for potential elevation of plasma-free hemoglobin (pfHb) during treatment. The use of pfHb testing allows detection of subclinical events with avoidance of propagating injury. Among 146 patients undergoing ECMO and VAD from 2009 to 2014, five patients experi...
متن کاملIn-Vitro Red Blood Cells Integrity and Morphology Changes after Passing Through Volumetric Peristaltic Infusion Pump
Background: It is not clear whether the use of volumetric peristaltic infusion pumps, affect the quality of the erythrocytes during packed cell transfusion or not. In the present study in vitro quality of red blood cells was assessed after using this type of infusion pumps in a prospective study. Materials and Methods: In this study 60 units of packed red cells were examined before and after p...
متن کاملTransplantation of lungs after ex vivo reconditioning in a patient on semi-elective long-term veno-arterial extracorporeal life support.
We present the case of a 41-year old patient suffering from end-stage pulmonary hypertension secondary to veno-occlusive disease who underwent implantation of a veno-arterial extracorporeal membrane oxygenator as a bridge to lung transplantation (LTx) due to significant deterioration of myocardial pump and liver function. After 33 days on support, lungs with extended donor criteria were offered...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Annals of thoracic surgery
دوره 98 1 شماره
صفحات -
تاریخ انتشار 2014