Inhibition of platelet deposition and lysis of intracoronary thrombus during balloon angioplasty using urokinase-coated hydrogel balloons.

نویسندگان

  • J F Mitchel
  • M A Azrin
  • D B Fram
  • M K Hong
  • S C Wong
  • J J Barry
  • L M Bow
  • T M Curley
  • F J Kiernan
  • D D Waters
چکیده

BACKGROUND Conventional balloon angioplasty of intracoronary thrombus is associated with a high incidence of abrupt closure, distal embolization, and no-reflow phenomenon. The purpose of this study was to assess a new technique for treating intracoronary thrombus consisting of the local delivery of urokinase directly to the angioplasty site with urokinase-coated hydrogel balloons. METHODS AND RESULTS We assessed local urokinase delivery using hydrogel balloons in four protocols. First, we evaluated the pharmacokinetics of urokinase delivery in vitro using 125I-labeled urokinase to measure drug loading onto hydrogel balloons, drug retention by the hydrogel polymer during blood exposure, and drug transfer from the balloon surface to the arterial wall during balloon dilatation. Second, we measured 125I-urokinase washoff from the hydrogel balloon in the intact circulation and intramural drug delivery during in vivo balloon angioplasty in 10 anesthetized New Zealand rabbits. Third, we assessed the effect of local urokinase delivery on 111In-labeled platelet deposition after balloon angioplasty in vivo in 13 porcine carotid or iliac arteries dilated with urokinase-coated balloons and compared them with contralateral control arteries dilated with saline-coated balloons. Finally, we determined the clinical efficacy of urokinase-coated balloons in 15 patients with intracoronary thrombus, including 7 who demonstrated abrupt thrombotic closure after conventional angioplasty. Between 241 and 1509 U urokinase could be loaded onto hydrogel balloons ranging in size from 2 to 8 mm. In vitro and in vivo studies demonstrated that hydrogel balloons absorbed significantly more urokinase and demonstrated less drug wash-off than nonhydrogel balloons (P < .01). Similarly, both in vitro and in vivo studies demonstrated urokinase transfer from the hydrogel to the arterial wall during balloon angioplasty, with greater intramural drug deposition with larger balloons (P < .01). Local urokinase delivery after in vivo porcine angioplasty decreased 111In-labeled platelet deposition by 47% compared with contralateral control vessels (P = .03). Use of urokinase-coated balloons in patients with intracoronary thrombus resulted in thrombus dissolution and reversal of abrupt closure in all cases, without evidence of distal embolization. CONCLUSIONS With the use of hydrogel-coated balloons, urokinase can be delivered locally to an angioplasty site. This technique decreases platelet deposition after in vivo balloon angioplasty and is efficacious in treating intracoronary thrombus in patients, including those with abrupt thrombotic closure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inhibition of Platelet Deposition and Lysis of Intracoronary Thrombus During Balloon Angioplast Using Urokinase- Coated Hydrogel Balloons

Background Conventional balloon angioplasty of intracoronary thrombus is associated with a high incidence of abrupt closure, distal embolization, and no-reflow phenomenon. The purpose of this study was to assess a new technique for treating intracoronary thrombus consisting of the local delivery of urokinase directly to the angioplasty site with urokinasecoated hydrogel balloons. Methods and Re...

متن کامل

Angioplast Using Urokinase- Coated Hydrogel Balloons

Background Conventional balloon angioplasty of intracoronary thrombus is associated with a high incidence of abrupt closure, distal embolization, and no-reflow phenomenon. The purpose of this study was to assess a new technique for treating intracoronary thrombus consisting of the local delivery of urokinase directly to the angioplasty site with urokinasecoated hydrogel balloons. Methods and Re...

متن کامل

Decreased platelet deposition and smooth muscle cell proliferation after intramural heparin delivery with hydrogel-coated balloons.

BACKGROUND In vitro and in vivo studies have demonstrated both anticoagulant and antiproliferative effects of heparin. The purpose of this study was to assess the effect of local intramural delivery of heparin, using heparin-coated hydrogel balloons, on platelet deposition and early smooth muscle cell proliferation after in vivo balloon angioplasty. METHODS AND RESULTS The effects of local he...

متن کامل

The experience use of drug-coated & non drug-coated balloons in arteriovenous fistula at a six months period: brief report

Background: The ineffectiveness of hemodialysis fistulas causes high costs and increases mortality and morbidity rates. The efficacy of drug-coated balloon and nondrug-coated balloon in dysfunctional arteriovenous Fistula was evaluated over six month period. Methods: In this randomized clinical trial, a total of a total of 50 hemodialysis patients who referred to Imam Reza Hospital in Kermansh...

متن کامل

Intracoronary urokinase for intracoronary thrombus accumulation complicating percutaneous transluminal coronary angioplasty in acute ischemic syndromes.

Intracoronary urokinase was used to treat flow-limiting intracoronary thrombus accumulation that complicated successful percutaneous transluminal coronary angioplasty (PTCA) during acute ischemic syndromes in 48 patients who were followed up through the acute phase of their illness. The study group comprised 10 patients with unstable angina pectoris, 18 patients with an evolving acute myocardia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 90 4  شماره 

صفحات  -

تاریخ انتشار 1994