Surgical technique: establishing a pre-clinical large animal model to test aortic valve leaflet substitute.

نویسندگان

  • Martin Schweiger
  • Walter Knirsch
  • Niko Cesarovic
  • Bernard Krüger
  • Martin Schmiady
  • Thomas Frauenfelder
  • Laura Frese
  • Hitendu Dave
  • Simon Philipp Hoerstrup
  • Michael Hübler
چکیده

To overcome current limitations of valve substitutes and tissue substitutes the technology of tissue engineering (TE) continues to offer new perspectives in congenital cardiac surgery. We report our experiences and results implanting a decellularized TE patch in nine sheep in orthotropic position as aortic valve leaflet substitute. Establishing the animal model, feasibility, cardiopulmonary bypass issues and operative technique are highlighted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prospects for percutaneous valve therapies.

Developmental efforts to achieve percutaneous catheterbased therapies for cardiac valve repair and replacement have advanced rapidly over the past several years. A variety of methods to treat mitral regurgitation (MR) and to replace aortic and pulmonic valves have already been successfully employed in patients. These innovative clinical transcatheter valve therapies were anticipated more than a...

متن کامل

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

Experience with the posterior leaflet extension technique for correction of rheumatic mitral insufficiency in children.

OBJECTIVE To describe the experience with the technique of posterior leaflet extension in children suffering of rheumatic mitral regurgitation. METHODS Between April 2002, and October 2007, 30 children, mean age 11.3 years, underwent correction of mitral insufficiency with the technique of posterior leaflet extension with a pericardial patch. Eight also received a Carpentier ring. Six childre...

متن کامل

A rare case of prosthetic aortic valve endocarditis complicated with multiple fistula to peri aortic structure

  Multiple aorto-cardiac cavity communications is very rare but important complication of prosthetic aortic valve endocarditis. The case below illustrates multiple aorto-cardiac cavity fistula formation following prostethic aortic valve endocarditis presented with slowly progressive symptoms of heart failure. A brief review of surgical reconstruction and the existing literature are presented, i...

متن کامل

Aortic valve replacement for quadricuspid valve: a lesson learnt from a negative experience.

Quadricuspid aortic valve is a rare congenital abnormality often associated with valve incompetence and requires surgical correction in adulthood. However, using a standard suture technique of aortic valve replacement, postoperative complete atrioventricular block is not uncommon because of the downward displacement of the supranumerary leaflet towards the membranous septum. We describe a sutur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of thoracic disease

دوره 8 12  شماره 

صفحات  -

تاریخ انتشار 2016