Evaluation of a new inhibitor test for isoamylase on Hitachi 705 analyser.
نویسندگان
چکیده
We describe a simple and rapid method for measuring pancreatic and salivary type amylases using the Hitachi 705 analyser. The determination is based on the inhibition of salivary amylase using an inhibitor isolated from wheat germ. The precision of the proposed method was very good: within-day precision varied from 0.4 to 2.5% (CV) and day-to-day precision from 2.2 to 3.7% (CV). The new application correlated well with another commercially available inhibition method. As the standardization is very stable and the assay procedure exactly the same as for the total amylase assay, the proposed method is suitable for routine isoamylase determination. Reference values for pancreatic and salivary amylase activities are presented.
منابع مشابه
Laboratory evaluation of the COBAS MIRA S random access analyser
The random access analyser COBAS MIRA S (Roche Diagnostics) was evaluated for two months. The instrument is a computer-controlled discrete analyser which can be run in a combination profile and single test mode. This instrument has special features, including an automatic cuvette segment changer, a reagent rack cooling system, an external keyboard and monitor, as well as a bar-code facility for...
متن کاملEvaluation of a new procedure for isoamylase measurement by selective inhibition.
The authors have evaluated a new procedure for the estimation of pancreatic and salivary isoamylase using a new selective inhibitor reagent (Enzamyl Isoamylase, Gödecke), Germany; composition covered by patent No. P 3404876.6). Provided the conditions of the assay presented here are correctly selected, a standard curve is not necessary and the activities of both isoenzymes can be calculated by ...
متن کاملA continuous method for the estimation of adenosine deaminase catalytic concentration in pleural effusions with a Hitachi 705 discrete analyser.
An assay of adenosine deaminase activity in pleural effusions is described. For the continuous determination of adenosine deaminase, the liberated ammonia is estimated by coupling the liberated NH3 with 2-oxoglutarate. The reaction is followed by the decrease of NADH absorbance at 340 nm. The assay was optimized for a Hitachi 705 analyser, with respect to pH, adenosine concentration and glutama...
متن کاملQuality assessment of the Reflotron System. A blood chemistry reagent strip analyser.
We tested the accuracy of the Reflotron System by comparing results given by this system for estimations of glucose, SGOT, SGPT, cholesterol and triglycerides on patients samples which were already analysed on either an autoanalyser HITACHI 705 or manually on CLIN ICON 4010. Reflotron estimations correlated well with both Hitachi and Clinicon estimations and the strips gave reproducible results...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie
دوره 24 11 شماره
صفحات -
تاریخ انتشار 1986