Predicting Central Venous Pressure by Measuring Femoral Venous Diameter Using Ultrasonography

نویسندگان

  • Akram Malik
  • Aftab Akhtar
  • Shoab Saadat
  • Salman Mansoor
چکیده

OBJECTIVES The objective of this exploratory study was to find out the correlation of femoral vein diameter (FVD) to central venous pressure (CVP) measurements and to derive a prediction equation to help ascertain the fluid volume status in a critical patient. PATIENTS AND METHODS This was a single-centered prospective cohort study designed and conducted by the critical care department of Shifa International hospital in Islamabad, Pakistan. Patients were enrolled from the medical and surgical intensive care units. The inclusion criteria consisted of patients > 18 years of age, and an intrathoracic central venous catheterization (CVC) in place for producing CVP waveform through the transducer. Patients having contraindications to CVP placement and those unable to lie supine were excluded from the study. Critical Care fellows with sufficient training in performing venous ultrasonography measured the FVD. They were blinded to the CVP values of the same patients. RESULTS The study included 108 patients. Among these 70/108 (64.8%) were males. Mean age was 53.85 (SD=16.74). The CVP and femoral vein diameter were measured in all patients. Mean CVP was 9.89 cmH2O (SD=3.46) and mean femoral vein diameter was 0.92 cm (SD=0.27). Multiple regression was used to generate a prediction model. FVD, age and sex of the patient were used as predictor variables to predict CVP diameter. The model was statistically significant with a p-value of < 0.000 and an F-value of 104.806. R-squared value for this model came out to be 0.744, thus the model was able to explain about 74.4% of the variance in the values observed for CVP. When controlled for age and sex, FVD was found highly correlated with CVP diameter with a p-value of < 0.000. A regression equation was derived that can be used to generate predicted values of CVP in millimeters of mercury with an R-square of 0.745 if FVD in centimeters is provided; CVP (cmH2O) = -0.039 + 10.718* FVD. CONCLUSIONS FVD was found highly correlated to CVP measurements and it suggests an alternate non-invasive method of ascertaining the volume status in the critically ill.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Internal Jugular Vein Height and Inferior Vena Cava Diameter Measurement using Ultrasound to Determine Central Venous Pressure: A Correlation Study.

OBJECTIVE To determine the correlation between central venous pressure (CVP) measured by conventional central venous access and ultrasonographic measurement of internal jugular vein (IJV) height and inferior vena cava (IVC) diameter. METHODS A prospective, cross-sectional, convenience sampling observational study. RESULTS 25 patients from the Emergency Department (ED) Universiti Kebangsaan ...

متن کامل

بررسی تأثیر استفاده از چک لیست ثبت اقدامات بر عملکرد پرستاران بخش مراقبت های ویژه در اندازه‌گیری فشار ورید مرکزی

  Background & Aim: The central venous pressure measurement is a common and important care provided by nurses in intensive units. The measurement should be according to the pre-defined standards. The purpose of this study was to evaluate the effect of using a checklist in measuring central venous pressure by nurses .   Methods & Materials: This was a nonequivalent group design on 70 nurses w...

متن کامل

بررسی ارزش تشخیصی میزانCaval index در تعیین فشار ورید مرکزی پایین در مقایسه با روش تهاجمی در بیماران بستری در ICU بیمارستان شهید باهنر کرمان

Introduction: Measurement of central venous pressure can be regarded as a beneficial guide in order to assess a patient's hemodynamic status, specifically in patient with sever sepsis and septic shock, for whom a central venous pressure of less than 8mmhg is considered as an indicator for aggressive intravenous fluid replacement. Therefore, this study aimed to investigate the ultrasonographic e...

متن کامل

Correlation between Central Venous Pressure and Inferior Vena Cava Sonographic Diameter; Determining the Best Anatomic Location

INTRODUCTION The correlation of central venous pressure (CVP) with inferior vena cava (IVC) sonographic diameter has been reported in several studies. However, few studies have attempted to find the best anatomic location of measurement. Therefore, the purpose of this study was determining the best anatomic location to find precise correlation between CVP and IVC diameter using transesophageal ...

متن کامل

اندازه گیری قطر قدامی – خلفی ورید اجوف تحتانی توسط سونوگرافی به عنوان یک روش غیر تهاجمی در تخمین میزان فشار ورید مرکزی در بیماران بستری در بخش مراقبت های ویژه

Introduction:The assessment of intravascular volume in severely traumatized patients or patients admitted in ICU is very essential. At present the accurate method for estimating the intravascular volume requirement is by measuring the CVP which is an invasive method. The measurement of IVC diameter by ultrasound has been suggested as an easily available and simple method for measuring the intra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2016