PURPOSE The aim of this study was to determine the efficacy of new light-emitting diode (LED) curing units in the hardening of Class II composite restorations. METHODS AND MATERIALS Disk specimens 2 mm in diameter and 2.5 mm thick were prepared from 2 composites (Vit-l-escence, shade A3, Ultradent; Herculite XRV, shade A2, Kerr) in the following manner. An extracted permanent molar tooth was prepared to receive a Class II restoration with proximal slot only. The tooth was sectioned horizontally on a plane above the gingival floor level such that the remaining depth of the proximal box was 4 mm. A Tofflemire matrix band and retainer were secured around the tooth. Composite specimens were placed below the tooth to coincide with the location of the slot opening at the bottom of the gingival floor. The specimens were subjected to light polymerization with various combinations of curing cycle and light unit: 1 of 3 continuous curing cycles (20 seconds, 40 seconds or 60 seconds) and 1 of 2 LED units (Utralume-5, Ultradent; IQ Smartlite, Dentsply) or a control quartz-tungsten-halogen (QTH) unit (Optilux 501, Kerr). Specimens were stored at 37 degrees C for 24 hours. A hardness tester was used to obtain 4 measurements of Knoop hardness number (KHN) for each surface (upper and lower) of each specimen. Relative hardness (RH) was calculated as the KHN of the lower surface divided by the KHN of the upper surface. Data were analyzed with analysis of variance (ANOVA) and Tukey"s test. RESULTS ANOVA indicated significant differences in mean RH among the groups (p < 0.001). RH increased with increasing curing time. For the 60-second cycle with Vit-l-escence composite, mean RH was 0.47, 0.25 and 0.39 for the Ultralume-5, IQ Smartlite and Optilux 501 curing units, respectively. For the 60-second cycle with Herculite XRV composite, mean RH was 0.71, 0.81 and 0.56 for the Ultralume-5, IQ Smartlite and Optilux 501 curing units, respectively. CONCLUSIONS In general, the 2 LED units performed as well as the QTH unit; however, brand of composite and curing cycle had significant effects on RH values.
منابع مشابه
Effect of Three Light Curing Protocols and Load Cycling on Microleakage of Class V Composite Restorations
Objective: Different methods have been suggested to overcome the polymerization shrinkage of composite restorations. Changing the light curing protocol to improve polymerization by using new light curing units is among these methods. The new devices are more efficient, portable and durable and produce less heat. This study aimed to assess the marginal microleakage of class V composite restora...
متن کاملمقایسه تأثیر دو نوع دستگاه لایت کیور با مدهای مختلف بر میزان میکرولیکیج ترمیمهای کلاس II کامپوزیتی
Background and Aims: One of the main disadvantages of light cured composite resin materials is polymerization shrinkage upon curing. This leads to the microleakage of restoration and finally failure of the restoration. The purpose of this study was to investigate the effect of two types of light curing devices with different modes on the microleakage of posterior composite filling in ...
متن کاملInfluence of Light-Curing Units on Color Stability of Composite Resins After Aging
Background and Aim: The use of composite restorations has increased in recent years. One of the most important problems with composite restorations is the loss of consistency between the composite and tooth color, which in most cases requires replacement. Materials and Methods: In this study, the color stability of 40 disc-shaped specimens (10 mm in diameter and 2 mm in height) from two types ...
متن کاملColor Stability of a Microhybrid Resin Composite Polymerized with LED and QTH Light Curing Units
Introduction: Discoloration of resin composites is a common reason for replacement of these restorations. The aim of this study was to eva-luate the influence of different light curing de-vices on color stability of a microhybrid resin composite. Materials and Methods: 80 disc-shaped speci-mens (8 mm in diameter, 2-mm height) were fabricated from filtek Z250 resin composite. Specimens wer...
متن کاملThe effect of three different curing methods on the microleakage of cl V posterior composite restorations
The effect of three different curing methods on the microleakage of cl V posterior composite restorations Dr. N. Mohammadi* - Dr. P. Alizadeh Oskoee* - Dr. S. Savadi Oskoee*- Dr. A . Soleyman zadeh** *- Assistant Professor of Esthetic & Operative Dentistry Dept. - Faculty of Dentistry – Tabriz University of Medical Sciences.*- Dentist. Background and Aim: Light-cured composites have become almo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal
دوره 73 3 شماره
صفحات -
تاریخ انتشار 2007