Porosity of temporary denture soft liners containing antifungal agents

نویسندگان

  • Jozely Francisca Mello Lima
  • Janaína Gomes Maciel
  • Juliana Hotta
  • Ana Carolina Pero Vizoto
  • Heitor Marques Honório
  • Vanessa Migliorini Urban
  • Karin Hermana Neppelenbroek
چکیده

Objective: To evaluate the porosity of a tissue conditioner (Softone) and a temporary resilient liner (Trusoft) modified by minimum inhibitory concentrations (MICs) of antifungal agents for Candida albicans biofilm. Material and Methods: The porosity was measured by water absorption, based on exclusion of the plasticizer effect. Initially, it was determined by sorption isotherms that the adequate storage solution for specimens (65×10×3.3 mm) of both materials was 50% anhydrous calcium chloride (S50). Then, the porosity factor (PF) was calculated for the study groups (n=10) formed by specimens without (control) or with drug incorporation at MICs (nystatin: Ny-0.032 g, chlorhexidine diacetate: Chx-0.064 g, or ketoconazole: Ke-0.128 g each per gram of soft liner powder) after storage in distilled water or S50 for 24 h, seven and 14 d. Data were statistically analyzed by 4-way repeated measures ANOVA and Tukey's test (α=.05). Results: Ke resulted in no significant changes in PF for both liners in water over 14 days (p>0.05). Compared with the controls, Softone and Trusoft PFs were increased at 14-day water immersion only after addition of Ny and Chx, and Chx, respectively (p<0.05). Both materials showed no significant changes in PF in up to 14 days of S50 immersion, compared with the controls (p>0.05). In all experimental conditions, Softone and Trusoft PFs were significantly lower when immersed in S50 compared with distilled water (p<0.05). Conclusions: The addition of antifungals at MICs resulted in no harmful effects for the porosity of both temporary soft liners in different periods of water immersion, except for Chx and Ny in Softone and Chx in Trusoft at 14 days. No deleterious effect was observed for the porosity of both soft liners modified by the drugs at MICs over 14 days of S50 immersion.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advances in Soft Denture Liners: An Update.

Soft denture liners are used in complete and partial removable dentures to distribute functional loads homogeneously on the denture-bearing tissues. These materials are recommended in cases of irregular bone resorption, bony undercuts, thin atrophic mucosa, immediate prosthesis, healing after implant placement, and for patients with bruxism and xerostomia. The resilient lining materials can be ...

متن کامل

Effect of Beverages on the Hardness and Tensile Bond Strength of Temporary Acrylic Soft Liners to Acrylic Resin Denture Base

STATEMENT OF PROBLEM Two potential problems commonly identified with a denture base incorporating a resilient liner are failure of the bond between acrylic resin and soft liner material, and loss of resiliency of the soft liner over time. Since patients may drink different beverages, it is important to evaluate their effects on physical properties of soft lining materials. PURPOSE The objecti...

متن کامل

Candida albicans biofilms and MMA surface treatment influence the adhesion of soft denture liners to PMMA resin.

The effect of Candida albicans biofilms and methyl methacrylate (MMA) pretreatment on the bond strength between soft denture liners and polymethyl methacrylate (PMMA) resin was analyzed. Specimens were prepared and randomly divided with respect to PMMA pretreatment, soft liner type (silicone-based or PMMA-based), and presence or absence of a C. albicans biofilm. Samples were composed of a soft ...

متن کامل

Surface Properties of Temporary Soft Liners Modified by Minimum Inhibitory Concentrations of Antifungals.

Evaluating the addition of minimum inhibitory concentrations (MICs) of antifungals for Candida albicans biofilm on the hardness and roughness of temporary denture soft liners. Specimens (n=8; 36×7×6 mm) of tissue conditioner (Softone) and resilient liner (Trusoft) were produced either without (control) or with incorporation of drugs at MICs: nystatin (0.032 g/mL), chlorhexidine diacetate (0.064...

متن کامل

A comparative evaluation of soft denture liners

Statement of problems: Two potential problems commonly identified with a denture base incorporating a resilient liner are a failure of the bond between the acrylic resin and resilient liner material and colonization of Candida albicans over time. Aims: This in vitro experimental study evaluated the shear and compressive bond strength as well as colonization of Candida albicans of commonly avail...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 24  شماره 

صفحات  -

تاریخ انتشار 2016