Panitumumab-Associated Encephalopathy after Accidental Intra-arterial Application through Dislocated Central Venous Access Device
نویسندگان
چکیده
Acute central nervous system (CNS) toxicity and immune-related side effects are increasingly recognized with the use of monoclonal antibodies for cancer therapy. Here, we report a patient who developed of acute-onset encephalopathy and coma, which began shortly after administration of panitumumab for the treatment of metastatic colorectal cancer. Echocardiography revealed that the drug had been infused into the left cardiac ventricle via a dislocated central venous line. Diffusion-weighted magnetic resonance imaging disclosed multiple cortical hyperintensities, which were preferentially located in the frontal lobes. While the neurological condition improved within a few days, the patient died 4 weeks later. It seems likely that the administration of the antibody via the intra-arterial route contributed to the development of this condition. Toxic encephalopathy may be a hitherto unrecognized complication of panitumumab treatment and should be taken into consideration in patients developing CNS symptoms undergoing this therapy.
منابع مشابه
Survey of a Practical Approach to Central Venous Catheterization in Pediatric Patients
Background Central venous catheter (CVC) is used for measuring hemodynamic variables, transfusion of blood, fluids and medications when peripheral vascular lack sufficiency. Unfortunately CVC is associated with many complications ranging from anxiety and discomfort for the patient to severe mechanical side effects such as arterial lacerations, pleural and pericardial injury as well as infection...
متن کاملAccidental carotid artery catheterization during attempted central venous catheter placement: a case report.
More than 2.1 million central venous catheters are placed annually. While carotid artery cannulation is rare, its effects can be devastating. Anesthesia providers frequently work with central venous catheters in the perioperative setting. Therefore, it is imperative that they be able to identify and react appropriately to carotid artery injury both in preexisting central lines and those that th...
متن کاملDescription of a new non-injectable connector to reduce the complications of arterial blood sampling.
Arterial cannulation is associated with complications including bacterial contamination, accidental intra-arterial injection and blood spillage. We performed a series of audits and experiments to gauge the potential for these, as well as assess the possible contribution of a new device, the Needle-Free Arterial Non-Injectable Connector (NIC), in reducing these risks. The NIC comprises a needle-...
متن کاملUltrasound imaging in vascular access.
Physicians spend a considerable amount of time and effort inserting catheters and needles into patients. Central venous catheters are the mainstay of measuring hemodynamic variables that cannot be assessed by noninvasive procedures. These catheters also allow hemodialysis, parenteral nutritional support, delivery of medications, and catecholamine administration. Arterial pressure catheters are ...
متن کاملCHAPTER 1 Vascular Access
Challenges 2 Femoral Approach 2 Standard of Technical Excellence 2 Technique The fl uoroscopically guided micropuncture access 3 Technical Tips 4 * * Angiography to check the location of femoral entry through a dilator 4 Preparations in obese patients 4 * Directing the needle 4 * If the wire cannot be inserted 5 * Sequential order for arterial and venous puncture 5 * * Kinked wire 5 * * Punctur...