Correcting nonlinear response of mercury cadmium telluride detectors in open path Fourier transform infrared spectrometry.
نویسندگان
چکیده
The effect of a nonlinear response of mercury cadmium telluride (MCT) detectors to photon flux is to cause a large offset and a slow variation in the zero-line of single-beam Fourier transform infrared (FT-IR) spectra, which dramatically reduce the accuracy to which strongly absorbing bands or lines can be measured. We describe a noniterative numerical technique by which the baseline offset can be corrected by adjusting the values of the maximum point in the interferogram (the "centerburst") and the points on either side. The technique relies on the presence of three spectral regions at which the signal is known to be zero. Two of these are found in all spectra, namely, the region below the detector cutoff and the high-wavenumber region just below the Nyquist wavenumber where the interferogram has been electronically filtered. In open path FT-IR measurements there are several regions where atmospheric water vapor and CO2 are totally opaque. We have selected the region around 3750 cm(-1). This algorithm is even shown to work well when the interferogram is clipped, i.e., the value at the centerburst exceeds the dynamic range of the analog-to-digital converter.
منابع مشابه
Completely automated open-path FT-IR spectrometry.
Atmospheric analysis by open-path Fourier-transform infrared (OP/FT-IR) spectrometry has been possible for over two decades but has not been widely used because of the limitations of the software of commercial instruments. In this paper, we describe the current state-of-the-art of the hardware and software that constitutes a contemporary OP/FT-IR spectrometer. We then describe advances that hav...
متن کاملNira Symposium July 7-8, 1982
Although Near Infrared Analysis (NIRA) as a technique can be traced back to the late 19th century, the first commercial instrumentation (Cary 14) was made available in the mid 1950's. Significant growth in the number of NIRA instruments used did not occur until the 1978-1982 period. During this time, the number of units utilized has grown at an annual compounded growth rate of well over sixty p...
متن کاملEmerging Trends in IRFPA Sensors
Significant developments have been taking place in the field of infrared sensors in recent years, to achieve higher resolution, wider spectral range, shorter response time and higher sensitivity (lower noise) in thermal imaging systems. Efforts are on to develop new technologies to produce infrared focal plane arrays (IR FPAs) with smaller pixel pitches, larger formats, higher frame rates, larg...
متن کاملNanotechnological Enhancement of Infrared Detectors by Plasmon Resonance in Transparent Conductive Oxide Nanoparticles
We investigated the use of plasmonic nanotechnology to enhance the performance of semiconductor infrared detectors. An increase of quantum efficiency, responsivity and specific detectivity is obtained by applying transparent conductive oxide (TCO) nanoparticles onto the surface of a photodetector. To this purpose we considered uncooled mercury cadmium telluride (HgCdTe) photoconductive detector...
متن کاملPerformance and application of a new planar array infrared spectrograph operating in the mid-infrared (2000-975 cm(-1)) fingerprint region.
A no-moving-part planar array infrared spectrograph (PA-IR) equipped with a 256 x 256 mercury cadmium telluride (MCT) focal plane array has been designed and constructed. The performance of the instrument, whose frequency range extends from 2000-975 cm(-1), has been assessed in terms of resolution, bandwidth, and signal-to-noise ratio. The PA-IR spectrograph is able to record spectra with an 8....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 80 13 شماره
صفحات -
تاریخ انتشار 2008