Wrapped Edge Gradient Coil for Mri-pet Animal Imaging

نویسندگان

  • V. Vegh
  • Q. M. Tieng
چکیده

Introduction: The medical imaging methods of Computed Tomography (CT), Magnetic Resonance Imaging (MRI) and Positron Emission Tomography (PET) are well established, each with their own advantages and disadvantages. There appears to be an ever increasing need to combine these modes of imaging, with the view of providing earlier diagnosis of disease, improved treatment planning and better patient care. Moreover, the concepts of MRI-PET and CT-PET are well established, but in the case of MRI-PET many challenges persist. Nevertheless, our work is aimed at MRI-PET scanners and primarily on the improvement of magnets and gradients [1]. Here we propose an open transverse gradient coil arrangement, which is suitable for small animal imaging. The z-gradient coil is known to be simpler to design; therefore main challenges are concerned with the design of xand y-gradient coil windings, whereby the x-gradient coil is the same as a y-gradient when a 90 rotation is applied.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Multiparametric PET/MRI with Silicon Photomultiplier PET and Ultra-High-Field MRI for Small-Animal Imaging.

UNLABELLED Visualization of biologic processes at molecular and cellular levels has revolutionized the understanding and treatment of human diseases. However, no single biomedical imaging modality provides complete information, resulting in the emergence of multimodal approaches. Combining state-of-the-art PET and MRI technologies without loss of system performance and overall image quality can...

متن کامل

Assessment of Reproducibility of Geometric Distortion in MRI using Phantom Measurements

Introduction:  Image  distortion  is  one  of  the  major  problems  of  magnetic  resonance  imaging  (MRI) for use in 3DMRI, velocity MRI, FMRI and radiotherapy treatment planning (RTTP). It is  widely known that the most obvious effect of the inhomogenity of the magnetic fields and the  nonlinearity  of  the  gradient  is  the  Geometric  Distortion  of  MR  tomograms.  In  this  study,  the...

متن کامل

Design of a Dynamically-Controlled Resistive Shield for a Combined PET and Superconducting MRI System for Small Animal Imaging

Introduction Efforts to combine anatomical and functional imaging modalities have resulted in the development and widespread use of PET/CT systems. PET/MRI would offer improved soft tissue contrast, highresolution anatomical information and would benefit longitudinal studies due to reduced dose. Combining conventional PET and MRI faces numerous technical challenges, particularly the sensitivity...

متن کامل

First results from a high-resolution small animal PET insert for PET/MRI imaging

University of Manitoba, Canada We have recently completed construction of a high resolution small animal PET insert designed for operation inside a Bruker 7T MRI. The PET insert is designed to achieve a 1 mm spatial resolution in the centre of its field of view (FOV) and fit within the 114 mm inner diameter of the Bruker BGA-12S gradient coil while accommodating the Bruker 35 mm volume RF coil ...

متن کامل

PET/CT versus body coil PET/MRI: how low can you go?

OBJECTIVES The purpose of this study was to evaluate if positron emission tomography (PET)/magnetic resonance imaging (MRI) with just one gradient echo sequence using the body coil is diagnostically sufficient compared with a standard, low-dose non-contrast-enhanced PET/computed tomography (CT) concerning overall diagnostic accuracy, lesion detectability, size and conspicuity evaluation. METH...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009