Inferior vena cava percentage collapse during respiration is affected by the sampling location: an ultrasound study in healthy volunteers.
نویسندگان
چکیده
OBJECTIVES Physicians are unable to reliably determine intravascular volume status through the clinical examination. Respiratory variation in the diameter of the inferior vena cava (IVC) has been investigated as a noninvasive marker of intravascular volume status; however, there has been a lack of standardization across investigations. The authors evaluated three locations along the IVC to determine if there is clinical equivalence of the respiratory percent collapse at these sites. The objective of this study was to determine the importance of location when measuring the IVC diameter during quiet respiration. METHODS Measurements of the IVC were obtained during quiet passive respiration in supine healthy volunteers. All images were recorded in B-mode, with cine-loop adjustments in real time, to ensure that maximum and minimum IVC dimensions were obtained. One-way repeated-measures analysis of variance (ANOVA) was used for comparison of IVC measurement sites. RESULTS The mean (+/-SD) percentage collapse was 20% (+/-16%) at the level of the diaphragm, 30% (+/-21%) at the level of the hepatic vein inlet, and 35% (+/-22%) at the level of the left renal vein. ANOVA revealed a significant overall effect for location of measurement, with F(2,35) = 6.00 and p = 0.006. Contrasts showed that the diaphragm percentage collapse was significantly smaller than the hepatic (F(1,36) = 5.14; p = 0.03) or renal caval index (F(1,36) = 11.85; p = 0.002). CONCLUSIONS Measurements of respiratory variation in IVC collapse in healthy volunteers are equivalent at the level of the left renal vein and at 2 cm caudal to the hepatic vein inlet. Measurements taken at the junction of the right atrium and IVC are not equivalent to the other sites; clinicians should avoid measuring percentage collapse of the IVC at this location.
منابع مشابه
The assessment of circulating volume using inferior vena cava collapse index and carotid Doppler velocity time integral in healthy volunteers: a pilot study
BACKGROUND Assessment of circulating volume and the requirement for fluid replacement are fundamental to resuscitation but remain largely empirical. Passive leg raise (PLR) may determine fluid responders while avoiding potential fluid overload. We hypothesised that inferior vena cava collapse index (IVCCI) and carotid artery blood flow would change predictably in response to PLR, potentially pr...
متن کاملInferior vena cava displacement during respirophasic ultrasound imaging
BACKGROUND Ultrasound measurement of dynamic changes in inferior vena cava (IVC) diameter can be used to assess intravascular volume status in critically ill patients, but published studies vary in accuracy as well as recommended diagnostic cutoffs. Part of this variability may be related to movements of the vessel relative to the transducer during the respiratory cycle which results in uninten...
متن کاملThe efficacy of inferior vena cava diameters and the jugular vein in assessing fluid resuscitation
Objective: Fluid resuscitation is necessary in almost all critical patients. The central venous pressure (CVP) is a well-established method of assessing resuscitation. Recently, there have been attempts to investigate less invasive methods like the diameters of inferior vena cava (IVC) or the jugular vein. We aimed to investigate this method in our research.Methods: Seventy eight critical...
متن کاملMultifactorial Neonatal Thrombosis in Inferior Vena Cava Dislodged to the Right Atrium: A Case Report
Background: Neonatal thrombotic diseases can cause mortality or serious morbidity and disability.Case report: In this report, we present a case of neonatal inferior vena cava thromboembolism with several underlyingfactors. Hereditary thrombophilia and genetic mutation in plasminogen activator inhibitor-1 and MTHFR A1298C genesin conjunction with cleft palate resulted in poor l...
متن کاملResident Journal Review: Ultrasound Measurements of the Inferior Vena Cava Collapse as a Determinate of Intravascular Volume Status
Introduction: In the 1980s cardiologists began using the size of the inferior vena cava (IVC) as seen on ultrasound (US) as a surrogate for the right sided filling pressures of the heart .1 Over time, this concept has been investigated in patients in a variety of settings such as hemodialysis clinics, cardiac units, intensive care units (ICU), and the emergency department (ED). The emergency me...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Academic emergency medicine : official journal of the Society for Academic Emergency Medicine
دوره 17 1 شماره
صفحات -
تاریخ انتشار 2010