Analytical Analysis of the Accuracy of HYPR LR in CE MRA

نویسندگان

  • H. Wu
  • A. A. Samsonov
  • J. Velikina
چکیده

true and HYPR LR profiles Figure 4. Artery waveforms of HYPR LR at edge pixel (left) and at center pixel (right). Figure 2. True waveforms of 3 objects (left) and HYPR LR images (right) reconstructed with kernels of widths: 3, 5, 12 at time point 5 (indicated by a black dashed line on the left. Figure 1. 1D object model and convolution kernel with wa shown as red area, wv as blue area Analytical Analysis of the Accuracy of HYPR LR in CE MRA

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vastly undersampled Isotropic Projection Reconstruction and HYPR for Time Resolved CE-MRA of the Peripheral Vessels

Introduction Vastly undersampled Isotropic Projection Reconstruction (VIPR) [1] techniques have been successfully utilized for time-resolved contrast-enhanced MR angiography (CE-MRA) studies. There are several benefits of a VIPR k-space trajectory, including the more benign nature of undersampling artifacts, which can facilitate higher undersampling factors. Due to the geometry of the legs, how...

متن کامل

Accelerated 3D Time-Resolved MR Angiography using Cartesian HYPR LR Reconstruction

INTRODUCTION In many MR applications, it is desirable to achieve high spatial and temporal resolution at the same time, such as contrast-enhanced MR angiography (CE-MRA). However, fully-sampled Cartesian acquisition for large matrices is extremely time consuming and precludes the simultaneous achievement of both goals. Several Cartesian undersampling methods, such as CAPR [1], TRIPPS [2] and va...

متن کامل

HYPR-L0: A Hybrid Technique for CE MRA with Extreme Data Undersampling Factors

Introduction. Many clinical applications, most notably contrast-enhanced (CE) time-resolved angiographic imaging, would benefit from volumetric coverage with high spatial and temporal resolution to capture the rapid passage of contrast material. For many applications such as intracranial examinations, these requirements necessitate data undersampling by as much as 40-100 times in 2D. Image reco...

متن کامل

Interleaved Variable Density Sampling with ARC Parallel Imaging and Cartesian HYPR for Dynamic MR Angiography

INTRODUCTION For MR applications such as contrast-enhanced MR angiography (CE-MRA), it is desirable to simultaneously achieve high spatial and temporal resolutions; however fully-sampled Cartesian acquisition of large matrices is time consuming. View sharing combined with parallel imaging (PI) improves temporal resolution [1], as does incoherent under-sampling with compressed sensing (CS) [2] o...

متن کامل

Individual component analysis of the multi-parametric cardiovascular magnetic resonance protocol in the CE-MARC trial

BACKGROUND The CE-MARC study assessed the diagnostic performance investigated the use of cardiovascular magnetic resonance (CMR) in patients with suspected coronary artery disease (CAD). The study used a multi-parametric CMR protocol assessing 4 components: i) left ventricular function; ii) myocardial perfusion; iii) viability (late gadolinium enhancement (LGE)) and iv) coronary magnetic resona...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008