Optical Quality of the Human Eye By

نویسندگان

  • F. W. CAMPBELL
  • R. W. GUBISCH
چکیده

1. Optical quality of the eye was measured at eight pupil sizes between 1-5 and 6-6 mm diameter by recording the faint light emerging from the eye; this light was reflected from the bright image of a thin line on the fundus. 2. The nature of the fundus reflexion was examined; it was found that the fundus acts very much like a perfect diffuser while retaining polarization. 3. Using the result that the fundus acts like a diffuser, the recorded line images were Fourier analysed to provide modulation transfer functions. These functions indicate an optical quality considerably higher than that found in previous physical studies. 4. Linespread profiles were then derived from the modulation transfer functions. These profiles are 40% narrower than those of previous physical studies for a 3 0 mm pupil. The narrowest profile occurred with a 2*4 mm pupil. 5. Our results demonstrate that physical and psychophysical studies can yield similar estimates of optical quality. The influence of optical factors not common to both techniques is discussed. Evidence for the existence of neural 'image sharpening' mechanisms is reviewed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of Optical Models Regarding the Human Eye

Introduction: Until now, many models have been presented for optical study of the human eye. In recent years, surgery on the anterior section of the eye (such as cataract and photo-refractive surgery) has increased, so a study on the optics of the eye and evaluation of vision quality has become more important. Material and Methods: In this article, some of these models are considered. They incl...

متن کامل

Three Dimensional Ultrasonography of the Eye and Measurement of Optical Nerve Sheet Diameter in Dog

Objective-  To determine the possibility of three-dimensional ultrasonography (3DUS) and measurement of optical nerve sheet by this method. Design- Descriptive study. Animals- 10 mixed normal dogs (5males, 5 females), age 1-1.5 year, and weighting 15±5 kg Procedure- 3D ultrasounds of the eyes were evaluated and the normal optical nerves in 3DUS images were measured using Volouson 730 pro....

متن کامل

Non-Blocking Routers Design Based on West First Routing Algorithm & MZI Switches for Photonic NoC

For the first time, the 4- and 5-port optical routers are designed by using the West First routing algorithm for use in optical network on chip. The use of the WF algorithm has made the designed routers to provide non-blocking routing in photonic network on chip. These routers not only are based on high speed Mach-Zehnder switches(Which have a higher bandwidth and more thermal tolerance than mi...

متن کامل

بررسی پایایی و تکرار پذیری دستگاه Spectral domain optical coherence tomography در اندازه گیری ضخامت ماکولا در چشمهای طبیعی قبل و بعد از گشاد کردن مردمک

Background: optical coherence tomography is one of the most valuable imaging techniques in the evaluation of macula. Objective: to investigate the repeatability and reproducibility of OCT  in measuring the macular thickness in normal eyes before and after pupil dilation. Methods: A total of 44 eyes were enrolled. All subjects underwent macular thickness measurement using the Cirrus SD-OCT ma...

متن کامل

Use of three-dimensional ultrasonography of the eye and measurement of optical long axis in dog

This study was conducted to determine the use of three-dimensional ultrasonography (3DU) in ocular imaging of the dog and measuring of its optical axis. 12 healthy mixed-breed dogs including 6 males and 6 females were studied. 3DU of the eyes were done using a 5–12 MHz linear trapezoid transducer. 3DU of the eyes were evaluated and the normal optical long axis through a line between the cornea ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1966