This study evaluated the diagnostic performance of ultrasound elastography (USE) using carotid arterial pulsation and determined the reproducibility of USE for thyroid nodules. A total of 148 patients with 173 thyroid nodules participated. The mean elasticity contrast index (ECI) was significantly higher in malignant nodules (3.1 ± 1.5) than in benign nodules (1.7 ± 0.8) (p < 0.001). When a cut-off ECI value of 3.5 was used, the diagnostic accuracy (78.6%) of gray-scale ultrasound (US) + ECI was the highest compared with that of the gray-scale US (76.9%) and ECI (67.1%). In 16 of 43 nodules (37.2%) with US-pathology, discordance could be correctly reclassified as benign (8 of 11) or malignant (8 of 32). The intra-class correlation coefficient for inter-observer agreement was 0.96, and those for intra-observer agreement were 0.97 and 0.98. Thyroid nodules with ECI values of >3.5 may have an additional value to increase the diagnostic accuracy for nodules with US-pathology discordance with reproducible results.
منابع مشابه
Thyroid nodule classification using ultrasound elastography via linear discriminant analysis.
The non-surgical diagnosis of thyroid nodules is currently made via a fine needle aspiration (FNA) biopsy. It is estimated that somewhere between 250,000 and 300,000 thyroid FNA biopsies are performed in the United States annually. However, a large percentage (approximately 70%) of these biopsies turn out to be benign. Since the aggressive FNA management of thyroid nodules is costly, quantitati...
متن کاملClinical Abstracts using Hitachi Real-time Tissue Elastography
OBJECTIVE: The purpose of this study was to evaluate whether ultrasound elastography performed by using carotid pulsation as a compression source and generating the systolic thyroid stiffness index (STSI) can be used as a pre-fine-needle aspiration (FNA) screening tool. METHODS: Ultrasound data previously acquired from 62 thyroid nodules in 59 patients who underwent a thyroid FNA were used. Pul...
متن کاملStrain US Elastography for the Characterization of Thyroid Nodules: Advantages and Limitation
Thyroid nodules, with their high prevalence in the general population, represent a diagnostic challenge for clinicians. Ultrasound (US), although absolutely reliable in detecting thyroid nodules, is still not accurate enough to differentiate them into benign and malignant. A promising novel modality, US elastography, has been introduced in order to further increase US accuracy. The purpose of t...
متن کاملUtility of the ultrasound elastographic systolic thyroid stiffness index in reducing fine-needle aspirations.
OBJECTIVE The purpose of this study was to evaluate whether ultrasound elastography performed by using carotid pulsation as a compression source and generating the systolic thyroid stiffness index (STSI) can be used as a pre-fine-needle aspiration (FNA) screening tool. METHODS Ultrasound data previously acquired from 62 thyroid nodules in 59 patients who underwent a thyroid FNA were used. Pul...
متن کاملUltrasound elastography for thyroid nodules: recent advances
Ultrasonography (US)-based elastography has been introduced as a noninvasive technique for evaluating thyroid nodules that encompasses a variety of approaches such as supersonic shear imaging and acoustic radiation force impulse imaging as well as real-time tissue elastography. However, the diagnostic performances for differentiating malignant thyroid nodules from benign ones with elastography ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ultrasound in medicine & biology
دوره 43 8 شماره
صفحات -
تاریخ انتشار 2017