Megavoltage x-ray skin dose variation with an angle using grid carbon fibre couch tops.

نویسندگان

  • Martin J Butson
  • Tsang Cheung
  • Peter K N Yu
چکیده

It is well known that a skin dose from high-energy x-ray radiation varies with the angle of beam incidence or the presence of a radiotherapy linear accelerator couch top material. This note investigates changes produced to the skin dose from a Varian carbon fibre grid couch top at differing angles of incidence for 6 MV x-rays as is often the case clinically. Results have shown that the skin dose can easily be measured using an EBT Gafchromic film whereby the delivered skin dose can be quantified to a high level of spatial resolution, not easily achieved with other skin dose detectors. Results have shown a significant increase in the skin dose specifically at the point of a cross-sectional carbon fibre grid. Values in % of the skin dose increased from approximately 27% (an open area within a 10 cm x 10 cm field) up to 55% (same field size) at the centre of the carbon fibre mesh strip (0 degrees incidence). This is compared to 19% of the skin dose for an open field of a 10 cm x 10 cm beam without the couch material present. At larger angles similar effects occur with values changing from 52% to 75% (60 degrees , 10 cm x 10 cm) in the open area and under the grid, respectively. This produces a wave effect for the skin dose. The average skin dose magnitude increases with the angle of incidence of the beam, ranging from 37.5% to 66% from 0 degrees to 60 degrees (10 x 10 cm), respectively. The symmetric wave nature of the skin dose profile skews to deliver an increased dose on the posterior side of the carbon fibre grid as the angle of incidence increases. Simulated fractional dose delivery on a phantom has shown that over 30 fractions the wave nature of the delivered skin dose is minimized due to the random nature of most patient positioning on the treatment couch. However, some variations are still present as the ratio of the open to grid area is approximately 4:1 and the dose spread is not necessarily completely averaged during a typical fractionated radiotherapy treatment. As such, if the treatment type results in a more rigorously positioned patient on the treatment couch, the wave nature of skin dose delivery may need to be taken into account.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Update of Couch Effect on the Attenuation of Megavoltage Radiotherapy Beam and the Variation of Absorbed Dose in the Build-up Region

Purpose: Fiber carbon is the most common material used in treating couch as it causes less beam attenuation than other materials. Beam attenuation replaces build-up region, reduces skin-sparing effect and causes target volume under dosage. In this study, we aimed to evaluate beam attenuation and variation of build-up region in 550 TxT radiotherapy couch.Materials and Methods: In this study, we ...

متن کامل

Variations in skin dose associated with linac bed material at 6 MV x-ray energy.

Treatment with radiotherapy x-rays at 6 MV energy produces a build-up effect whereby a smaller dose is delivered to the patient's skin compared to the tumour dose. With anterior fields, no material is normally placed over the patient's skin, thus providing the maximum skin sparing possible with the beam configuration used. A posterior beam normally passes through the treatment couch top and inc...

متن کامل

A validation of carbon fiber imaging couch top modeling in two radiation therapy treatment planning systems: Philips Pinnacle3 and BrainLAB iPlan RT Dose

BACKGROUND Carbon fiber (CF) is now the material of choice for radiation therapy couch tops. Initial designs included side metal bars for rigidity; however, with the advent of IGRT, involving on board imaging, new thicker CF couch tops without metal bars have been developed. The new design allows for excellent imaging at the expense of potentially unacceptable dose attenuation and perturbation....

متن کامل

An Update of Couch Effect on the Attenuation of Megavoltage Radiotherapy Beam and the Variation of Absorbed Dose in the Build-up Region

PURPOSE Fiber carbon is the most common material used in treating couch as it causes less beam attenuation than other materials. Beam attenuation replaces build-up region, reduces skin-sparing effect and causes target volume under dosage. In this study, we aimed to evaluate beam attenuation and variation of build-up region in 550 TxT radiotherapy couch. MATERIALS AND METHODS In this study, we...

متن کامل

Grid: A location dependent intensity modulated radiotherapy for bulky tumors

Background: An effective method for management of large and bulky malignant tumors. This treatment modality is also known as Specially Fractionated Radiation Therapy (SFRT). In this treatment technique a grid block converted the open radiation field into a series of pencil beams. Dosimetric characteristics of an external beam grid radiation field have been investigated using experimental and Mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 52 20  شماره 

صفحات  -

تاریخ انتشار 2007