Effect of glucose degradation products on human peritoneal mesothelial cell function.
نویسندگان
چکیده
Bioincompatibility of conventional glucose-based peritoneal dialysis fluids (PDF) has been partially attributed to the presence of glucose degradation products (GDP) generated during heat sterilization of PDF. Most previous studies on GDP toxicity were performed on animal and/or transformed cell lines, and the impact of GDP on peritoneal cells remains obscure. The short-term effects of six identified GDP on human peritoneal mesothelial cell (HPMC) functions were examined in comparison to murine L929 fibroblasts. Exposure of HPMC to acetaldehyde, formaldehyde, glyoxal, methylglyoxal, furaldehyde, but not to 5-hydroxymethyl-furfural, resulted in dose-dependent inhibition of cell growth, viability, and interleukin-1beta (IL-1beta)-stimulated IL-6 release; for several GDP, this suppression was significantly greater compared with L929 cells. Although the addition of GDP to culture medium at concentrations found in PDF had no major impact on HPMC function, the exposure of HPMC to filter-sterilized PDF led to a significantly smaller suppression of HPMC proliferation compared to that induced by heat-sterilized PDF. The growth inhibition mediated by filter-sterilized PDF could be increased after the addition of clinically relevant doses of GDP. These effects were equally evident in L929 cells. In conclusion, GDP reveal a significant cytotoxic potential toward HPMC that may be underestimated in test systems using L929 cells. GDP-related toxicity appears to be particularly evident in experimental systems using proliferating cells and the milieu of dialysis fluids. Thus, these observations may bear biologic relevance in vivo where HPMC are repeatedly exposed to GDP-containing PDF for extended periods of time.
منابع مشابه
3,4-Dideoxyglucosone-3-ene as a mediator of peritoneal demesothelization.
BACKGROUND The mesothelium contributes significantly to the functional, structural and homeostatic properties of the peritoneum. Bioincompatible peritoneal dialysis solutions contribute to mesothelial cell loss during chronic peritoneal dialysis. Cell death has been implicated in mesothelial cell loss, but the molecular mechanisms have not been adequately characterized. We now report the modula...
متن کاملProlonged exposure to glucose degradation products impairs viability and function of human peritoneal mesothelial cells.
Bioincompatibility of peritoneal dialysis fluids (PDF) has been linked to the presence of glucose degradation products (GDP). Previous experiments have shown that short-term exposure to several GDP at concentrations found in commercially available PDF had no significant effect on human peritoneal mesothelial cells (HPMC). During continuous ambulatory peritoneal dialysis, however, cells are cont...
متن کاملThe triggering of human peritoneal mesothelial cell apoptosis and oncosis by glucose and glycoxydation products.
BACKGROUND Peritoneal dialysis fluids (PDFs) have been shown to alter mesothelial cell functions. To further determine the mechanisms involved, we investigated the effects of glucose, glucose degradation products (GDPs) and advanced glycation end products (AGEs) on the inhibition of human peritoneal mesothelial cell (HPMC) proliferation and the induction of apoptosis and oncosis. METHODS Four...
متن کاملImproved in vitro biocompatibility of bicarbonate-buffered peritoneal dialysis fluid.
BACKGROUND Conventional peritoneal dialysis fluids (PDFs) have been shown to damage the mesothelial layer and are associated with the development of peritoneal fibrosis and neoangiogenesis. New-generation PDFs have therefore been developed with physiological pH and reduced levels of glucose degradation products (GDPs), precursors of advanced glycation end products (AGEs). In this work, we evalu...
متن کاملRe: effects of low-glucose degradation product solution on peritoneal membrane characteristics in peritoneal dialysis patients: a 3-year follow-up study.
Dear Editor, In the past issue of the Iranian Journal Kidney Disease, Park and colleagues compared the standard peritoneal dialysis (PD) solution to the low glucose degradation products (GDP) solution in a 3-year follow-up.1 Peritoneal dialysis (PD) is an effective and established form of renal replacement therapy in end -stage renal disease over the past 30 years, which is used by approximatel...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American Society of Nephrology : JASN
دوره 11 4 شماره
صفحات -
تاریخ انتشار 2000