Astigmatism of Skew Pencils in Qptical Systems Containing Toric Surfaces
نویسنده
چکیده
Toric refracting surfaces are used chiefly in two classes of optical systems, spectacle lenses, and anamorphotic photographic and projection objectives. In spectacles the toric surfaces are arranged to correct the axial astigmatism of t he eye, and in anamorphotic systems two or more toric (possibly cylindrical) surfaces are included to give stigmatic imagery with different magnifications in different directions in t he image plane. "When the axial pencil is refracted by a toric,3 some astigmatism is in trodu ced; if a pencil is incident obliquely, either cent rally or eccentrically , astigmatism of different magnitude is in troduced. It is therefore desirable in the case of both types of optical systems mentioned above to determine the astigmatism of obliquely incident pencils, in order to assess the imagery in the outer par ts of the field. This is t he problem which was studied in the work to be described. The problem arose in connection with spectacle lenses and may be outlined as follows: Figure 1 shows fron t and side views of a spectacle lens wit h toric surface ; 0 is the center of the lens, C is t he center of rotation of the eye, and PI, P2 , P3 are points of incidence of the chief rays of oblique pencils. L et the meridian and equatorial sections of the toric be, respectively , in the ver tical and horizontal planes OPt and OP3 • Then the problem for chief rays passing through the axis and tlu'ough PI and P 3 is t rivial. The chief ray itself can be traced by the ordinary ray-tracing formulas for meridian rays and spherical surfaces, and the astigmatism can be determined by the usual methods for close sagittal and tangen tial fans, with the sligh t difference that the curva tures of the refracting surface in tbe two directions are no t eq Llal (see eq (8) ).
منابع مشابه
Surgical management of astigmatism with toric intraocular lenses.
Correction of corneal astigmatism is a key element of cataract surgery, since post-surgical residual astigmatism can compromise the patient's uncorrected visual acuity. Toric intraocular lenses (IOLs) compensate for corneal astigmatism at the time of surgery, correcting ocular astigmatism. They are a predictable treatment. However, accurate measurement of corneal astigmatism is mandatory for ch...
متن کاملVector analysis of corneal and refractive astigmatism changes following toric pseudophakic and toric phakic IOL implantation.
PURPOSE To determine the efficacy of the astigmatism correction following toric intraocular lens (IOL) and toric phakic IOL (pIOL) implantation in eyes with no previous ocular surgery and in postkeratoplasty (PKP) eyes. In addition, changes in corneal astigmatism were determined. METHODS Astigmatism was analyzed in 35 eyes with an AcrySof toric IOL, 35 eyes with an Artiflex toric pIOL, 50 eye...
متن کاملNumerical Computation of Deflating Subspaces of Skew-Hamiltonian/Hamiltonian Pencils
We discuss the numerical solution of structured generalized eigenvalue problems that arise from linear-quadratic optimal control problems, H∞ optimization, multibody systems, and many other areas of applied mathematics, physics, and chemistry. The classical approach for these problems requires computing invariant and deflating subspaces of matrices and matrix pencils with Hamiltonian and/or ske...
متن کاملA Structured Staircase Algorithm for Skew-symmetric/symmetric Pencils
A STRUCTURED STAIRCASE ALGORITHM FOR SKEW-SYMMETRIC/SYMMETRIC PENCILS RALPH BYERS , VOLKER MEHRMANN , AND HONGGUO XU Abstract. We present structure preserving algorithms for the numerical computation of structured staircase forms of skew-symmetric/symmetric matrix pencils along with the Kronecker indices of the associated skew-symmetric/symmetric Kronecker-like canonical form. These methods all...
متن کاملEffects of preoperative corneal astigmatism orientation on results with a low-cylinder-power toric intraocular lens.
PURPOSE To evaluate refractive results with a low-cylinder-power toric intraocular lens (IOL) and the effect of preoperative corneal astigmatism orientation on results. SETTING Private practice, Jackson, Michigan, USA. DESIGN Comparative case series. METHODS This retrospective review of clinical records comprised patients with 0.75 to 1.38 diopters (D) of preoperative corneal astigmatism ...
متن کامل