Recommendations on stent manufacture, implantation and utilization
نویسندگان
چکیده
The neologism ‘stent’ has irrevocably entered the English medical vocabulary as a noun as well as a verb. It allegedly dates back to the English dentists Charles T. Stent (1807–1885) and his sons Charles R. Stent (1845– 1901) and Arthur H. Stent (1859–1900) who used to support poorly aligned teeth with a special apparatus. Others have traced the word back to the 14th century. The first mention of the word stent in the (non-dentistry) medical literature can be found in a paper on reconstruction of the biliary duct in dogs in 1954. Charles Dotter employed the term stent for vascular implants in 1983 when he presented the first clinical experience with a percutaneously implanted vascular endoprosthesis based on prior canine experiments in 1969. As a further development to heat-expandable stents, Maass published animal data in 1983 and 1984 on mechanically self-expanding stents for use in peripheral arteries. In 1985, a spring-loaded self-expanding stent was described by Gianturco’s group, followed by the first balloonexpandable stent by Palmaz and a self-expanding mesh-stent by Rousseau and Sigwart. In 1987 the first animal studies on coronary stenting were published . The first human implantation using the self-expanding mesh-stent or Wallstent was carried out by Puel on 28 March 1986. Its initial development had been hampered by several problems. First, the risk of subacute thrombotic coronary artery closure several days after the procedure emerged as a novel, stent-specific hazard prompting complex anticoagulation regimens, associated with increased bleeding and prolonged hospital stays. Second, shortly after the clinical introduction of the stent, Medinvent (the Swiss firm producing the Wallstent) became part of the American Pfizer company. Pfizer had been beset by major difficulties with a heart valve of their subsidiary Shiley, and thus proceeded with extreme caution in launching the stent because it was felt to be another implantable device potentially necessitating a later callback campaign. Following the unavailability of the Wallstent, the Palmaz–Schatz, the Gianturco– Roubin and the Wiktor stents developed concurrently, but were only available to selected centres under strict research regulations. Third, the limitation of stenting to acute and threatening occlusions after coronary angioplasty yielded early success and complication rates that were not always competitive with those of routine angioplasty. Insufficient consideration was given to the fact that the stent much improved the otherwise dismal outcome of these patients, and randomized studies were lacking. Fourth, other new devices, such as the laser, rotational ablation, and directional atherectomy, frequently utilized in low-risk situations in contrast to the stent, appeared to many as more attractive as they did not require prolonged and enforced anticoagulation. The sobering accounts on the first roughly 100 patients with a coronary stent fraught with all the adverse risk factors enumerated above, amplified by an explicit editorial, all but extinguished the flickering flame of stent enthusiasm in 1991. It was not until several years later that the common error of looking at the stent as just another new device for coronary angioplasty was first challenged and then corrected by the results of well designed randomized trials. These trials, initiated by Serruys and his colleagues from the Benestent group, proved that primary stent implantation in elective cases could reduce angiographic restenosis rates and improve the patient’s clinical outcome, as compared with balloon angioplasty. Eventually, following the lead of Colombo and others, the implantation technique was improved by focusing on full expansion, adequate deployment of the stent using intravascular ultrasound, and by the use of simplified and more effective anticoagulation protocols. Since then, the stent has gained ground at an incredible speed. In 1995 it was used in most coronary angioplasty procedures at leading centres and in 30–60% of all cases at other centres. Over 20 stent
منابع مشابه
Safety, Efficacy and Clinical Outcome of Direct Stent Implantation
Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...
متن کاملValidation for coronary stenting: a permanent implant for interventional cardiology.
[1] Pyorala K, De Backer G, Graham I. Poole-Wilson PA, Wood D on behalf of the Task Force. Prevention of coronary heart disease in clinical practice. Recommendations of the Task Force of the European Society of Cardiology, European Atherosclerosis Society and the European Society of Hypertension. Eur Heart J 1994; 15: 1300-31. [2] The Task Force on the Management of Acute Myocardial Infarction ...
متن کاملCoronary Endothelial Dysfunction after Drug-Eluting Stent Implantation
Problem statement: Stent thrombosis, which may occur even one year after stent implantation, is a drawback of Drug-Eluting Stents (DES). Among the variety of causes of stent thrombosis after DES implantation, coronary endothelial dysfunction manifested or exaggerated by DES implantation should not be overlooked. This review article summarizes previous reports on coronary endothelial dysfunction...
متن کاملApplication of 64-slice spiral computed tomography angiography in a follow-up evaluation after coronary stent implantation: A Chinese clinical study
Background: This study assessed the application value of 64-slice spiral computed tomography angiography (CTA) in a follow-up evaluation of patients receiving coronary stent implantation. Materials and Methods: A total of 468 patients who underwent percutaneous coronary intervention (PCI) at our hospital between January 2013 and October 2016 were selected for this study. Coronary angiography an...
متن کاملIntracoronary ultrasound observations during stent implantation.
T he Palmaz-Schatz stent has been used successfully to improve primary angioplasty results, to treat large coronary dissections, or to prevent impending closure of the lumen.-1-5 The determination of successful stent implantation is based on the angiographic appearance. However, angiographic projection imaging may not reveal the three-dimensional geometry that is necessary to appreciate full ex...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -