Efficacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucoma.
نویسندگان
چکیده
AIMS To evaluate the efficacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucomas. METHODS This retrospective study reviewed the final intraocular pressure, visual outcome, and incidence of complications in all patients with the Ahmed glaucoma valve implant performed at the Prince of Wales Hospital, Hong Kong, between June 1996 and November 1998. RESULTS A total of 65 eyes from 60 patients were treated with the Ahmed glaucoma implant. At a mean follow up (SD, median) of 21.8 (9.2, 28. 0) months (range 6-37 months), the mean intraocular pressure was reduced from 37.0 (SD 12.1) mm Hg before the implant surgery to 16.1 (12.4) mm Hg at the last follow up after surgery. The success rate of intraocular pressure control of <22 mm Hg was achieved in 73.8% of operated eyes. Transient postoperative hypotony with shallow anterior chamber occurred in 10.8% of cases. The most common postoperative complication was the formation of encapsulated bleb (24.6%). CONCLUSIONS The Ahmed glaucoma valve implant appears to be effective and relatively safe for treating complicated glaucomas in Chinese eyes. The success rate is comparable with those reported in non-Asian eyes. Formation of postoperative encapsulated bleb is, however, more commonly encountered.
منابع مشابه
EYcacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucoma
Aims—To evaluate the eYcacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucomas. Methods—This retrospective study reviewed the final intraocular pressure, visual outcome, and incidence of complications in all patients with the Ahmed glaucoma valve implant performed at the Prince of Wales Hospital, Hong Kong, between June 1996 and November 1998. Results—A to...
متن کاملGlaucoma Surgery in Pregnancy: A Case Series and Literature Review
AbstractGlaucoma management in pregnant patients is a real challenge, especially when the glaucoma is not controlled with medications. We report the results of 6 incisional glaucoma surgeries for the management of medically uncontrolled glaucoma patients during pregnancy. This retrospective, case series was conducted on the 6 eyes of 3pregnant patients with uncontrolled glaucoma using maximum t...
متن کاملAhmed glaucoma valve implant for childhood glaucoma in Sturge-Weber syndrome with choroidal hemangioma.
We present our experience with implantation of an Ahmed glaucoma valve in a 9-year-old girl with Sturge-Weber syndrome with choroidal hemangioma. In this case of childhood glaucoma, the choice of surgical procedure should be based on the efficacy and elimination of intra-and post-operative complications. An Ahmed glaucoma valve offered safety and efficacy in controlling glaucoma. This technique...
متن کاملThe Clinical Use of Ahmed Valve Implant as an Aqueous Shunt for Control of Uveitic Glaucoma in Dogs
Objective: Safety and efficacy of Ahmed glaucoma valve implantation for the management of uveitis induced glaucoma evaluated on the five dogs with uncontrollable glaucoma. Materials and Methods: Ahmed Glaucoma Valve (AGV®; New World Medical, Rancho Cucamonga, CA, USA) is a flow restrictive, nonobstructive self-regulating valve system. Preoperative ocular evaluation included direct ophthalmoscop...
متن کاملThe Ahmed Glaucoma Valve in Refractory Glaucoma: Experiences in Southwest Ethiopia
BACKGROUND The management of refractory glaucoma is a challenging task for any glaucoma surgeon. This study is aimed to evaluate the efficacy of Ahmed Glaucoma Valve implantation in refractory glaucomas in South-West Ethiopia. METHODS A retrospective review was conducted on the charts of consecutive patients treated with Ahmed glaucoma valve implantation at Jimma University Specialized Hospit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 84 7 شماره
صفحات -
تاریخ انتشار 2000