Comparison of 64-slice CT with gated SPECT for evaluation of left ventricular function.
نویسندگان
چکیده
UNLABELLED Precise and reliable assessment of left ventricular (LV) function and dimensions is prognostically important in cardiac patients. As the integration of SPECT and multislice CT into hybrid scanners will promote the combined use of both techniques in the same patient, a comparison of the 2 methods is pertinent. We aimed at comparing LV dimensions, muscle mass, and function obtained by electrocardiographically gated 64-slice CT versus gated-SPECT. METHODS Sixty patients (mean age, 64 +/- 8 y) referred for evaluation of coronary artery disease underwent 99mTc-tetrofosmin gated SPECT and 64-slice CT within 4 +/- 2 d. LV ejection fraction (LVEF), end-systolic volume (ESV), and end-diastolic volume (EDV) from CT were compared with SPECT. Additionally, LV muscle mass and quantitative regional wall motion were assessed in 20 patients with both methods. RESULTS CT was in good agreement with SPECT for quantification of LVEF (r = 0.825), EDV (r = 0.898), and ESV (r = 0.956; all P < 0.0001). LVEF was 59% +/- 13% measured by SPECT and slightly higher but not significantly different by CT (60% +/- 12%; mean difference compared with SPECT, 1.1% +/- 1.7%; P = not significant). A systematic overestimation using CT for EDV (147 +/- 60 mL vs. 113 +/- 52 mL; mean difference, 33.5 +/- 23.1 mL) and ESV (63 +/- 55 mL vs. 53 +/- 49 mL; mean difference, 9.3 +/- 15.9 mL; P < 0.0001) was found compared with SPECT. A good correlation for muscle mass was found between the 2 methods (r = 0.868; P < 0.005). However, muscle mass calculated by SPECT was significantly lower compared with CT (127 +/- 24 g vs. 148 +/- 37 g; mean difference, 23.0 +/- 12.2 g; P < 0.001). The correlation for regional wall motion between the 2 methods was moderate (r = 0.648; P < 0.0001). CONCLUSION LVEF and LV functional parameters as determined by 64-slice CT agree over a wide range of clinically relevant values with gated SPECT. However, interchangeable use of the 2 techniques should be avoided for LV volumes, muscle mass, and regional wall motion because of variances inherent to the different techniques.
منابع مشابه
Comparison of 64-Slice CT with Gated SPECT for Evaluation of Left Ventricular Function
Precise and reliable assessment of left ventricular (LV) function and dimensions is prognostically important in cardiac patients. As the integration of SPECT and multislice CT into hybrid scanners will promote the combined use of both techniques in the same patient, a comparison of the 2 methods is pertinent. We aimed at comparing LV dimensions, muscle mass, and function obtained by electrocard...
متن کاملDiastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography
Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiogr...
متن کاملThe role of oral dipyridamole stress gated SPECT in assessing the response of the left ventricle to stress: Re-evaluation of an old method
Introduction: We aimed to assess whether the vasodilator effect of oral dipyridamole on the left ventricular systolic function in patients with suspected CAD is different from that of intravenous (IV) dipyridamole using Tc-99m MIBI myocardial perfusion gated SPECT. Methods: Eighty-nine patients (17 M / 72 W; 61 ± 10 years) were enrolled in this study. The patients underwent a dipyridamole stre...
متن کاملDipyridamole stress and rest gated 99mTc-sestamibi myocardial perfusion SPECT: left ventricular function indices and myocardial perfusion findings
Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studie...
متن کاملPerformance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT
Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 48 6 شماره
صفحات -
تاریخ انتشار 2006