Laser Ablation ICP-MS Analysis of Marine Sediments from the Oxfordian (Late Jurassic): A Comparison of Three Preparation Techniques

نویسندگان

  • B. Müller
  • M. Guillong
چکیده

Trace element analyses of marine sediments provide important information on past oceanographic and climatic changes. Five samples consisting of grey to black marls with layers of carbonate nodules (so called “Terre Noires” from a 102 m long profile from Oze, Southern France) were prepared in three different ways to find the most appropriate preparation technique for major, minor and trace elements by LA-ICP-MS analysis: 1. Powder pills were dry pressed after milling 30 g of a sample down to fine powder (around 1 μm in size). 2. Cubes of marl were cut out of the hand specimens and analyzed directly after polishing. 3. Fused glasses were prepared by mixing a 5:1 ratio of flux (Li2B4O7) to finely ground samples. The LA ICP-MS analysis was performed using a pulsed 193 nm ArF Excimer laser (with a homogenized beam profile) in combination with an ELAN 6100 DRC ICP-MS. Samples were measured for the following elements: Na, Mg, Al, Si, P, K, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Rb, Sr, Y, Zr, Nb, Sn, Cs, Ba, La, Ce, W, Tl, Pb, Bi, U. Analytical precision based on replicate analyses depends strongly on the preparation method. Typical RSDs (relative standard deviations) from analyses of the mentioned elements in powder pills range between 5 % (Mn, Sr) and 50 % (Zn). For the cubes generally higher RSDs were found than in the powder pills, between 5 % (Sc) and 90 % (Cu). Generally, RSDs from fused glass pills were lower than 6 %. Heterogeneous element distribution in the cubes leads to non-representative sampling by the laser and these data can therefore not be considered for interpretation of the results. From the statistics it can be seen that the analyses of powder pills are better but the RSDs are still unacceptably high. Statistically the best analytical results are obtained from the homogeneous glass pills. Therefore lithium borate fused glasses is the preferred method of preparation for sediment analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heavy metals in coastal sediments of South Caspian Sea: natural or anthropogenic source?

This paper focuses on heavy metal distribution patterns in sediments of central Guilan (CG) and east Mazandaran (EM) in the south Caspian Sea coasts, north of Iran. Sediment sub-samples were retrieved from core and surficial samples in different environments of marine and coastal lagoons as well as coastal outcrops. Inductively Coupled Plasma Mass Spectrometry and Atomic Emission Spectrometry (...

متن کامل

Stratigraphy of the Upper Jurassic shallow marine carbonates of the Moghan area (NW Iran), with paleobiogeography implication on Alveosepta jaccardi (Schrodt, 1894)

A micropaleontological study has been carried out on the samples collected from the Sarv Abad section, the oldest and only known Jurassic sedimentary rocks cropping out in the Moghan area. Studied sequence consists of carbonates bounded at both base and top by clastic deposits. Studied carbonate deposits provide an assemblage of benthic foraminifera as well as calcareous algae. The stratigraphi...

متن کامل

A comparison of techniques for measuring the trace element content of human teeth: laser ablation ICP-MS versus solution ICP-MS of micromilled enamel

Through analysis of their chemical composition, human teeth may serve as retrospective bioindicators of preand postnatal nutrition and exposures to environmental pollutants. The research presented here explores the agreement of laser ablation ICP-MS and solution ICP-MS analyses aimed at capturing temporal changes in the trace element composition of enamel. Good agreement was found for LA-ICP-MS...

متن کامل

Analysis of trace metals in comparison of laser-induced breakdown spectroscopy with LA-ICP-MS

Laser-induced breakdown spectroscopy (LIBS) and LA-ICP-MS (laser ablation inductively coupled plasma mass-spectrometry) were used for the detection of trace metals in a solid matrix consisting of KBr and two oxides. The results of both methods were compared to investigate the strengths and weaknesses of both methods. Most difficulties for quantification of LIBS data are related to matrix effect...

متن کامل

Major element analysis of natural silicates by laser ablation ICP-MS†‡

The complete chemical analysis of natural silicates has previously been accomplished only by combining laser ablation ICP-MS with electron microprobe (EMP) analysis to provide complementary information on major element constituents. Here, we present a method for laser ablation ICP-MS analysis of major elements in silicate glasses and minerals that, when applied using a 193 nm laser system coupl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010