Comparison of effective radiation doses from X-ray, CT, and PET/CT in pediatric patients with neuroblastoma using a dose monitoring program.
نویسندگان
چکیده
PURPOSE We aimed to evaluate the use of a dose monitoring program for calculating and comparing the diagnostic radiation doses in pediatric patients with neuroblastoma. METHODS We retrospectively reviewed diagnostic and therapeutic imaging studies performed on pediatric patients with neuroblastoma from 2003 to 2014. We calculated the mean effective dose per exam for X-ray, conventional computed tomography (CT), and CT of positron emission tomography/computed tomography (PET/CT) from the data collected using a dose monitoring program (DoseTrack group) since October 2012. Using the data, we estimated the cumulative dose per person and the relative dose from each modality in all patients (Total group). The effective dose from PET was manually calculated for all patients. RESULTS We included 63 patients with a mean age of 3.2±3.5 years; 28 had a history of radiation therapy, with a mean irradiated dose of 31.9±23.2 Gy. The mean effective dose per exam was 0.04±0.19 mSv for X-ray, 1.09±1.11 mSv for CT, and 8.35±7.45 mSv for CT of PET/CT in 31 patients of the DoseTrack group. The mean estimated cumulative dose per patient in the Total group was 3.43±2.86 mSv from X-ray (8.5%), 7.66±6.09 mSv from CT (19.1%), 18.35±13.52 mSv from CT of PET/CT (45.7%), and 10.71±10.05 mSv from PET (26.7%). CONCLUSION CT of PET/CT contributed nearly half of the total cumulative dose in pediatric patients with neuroblastoma. The radiation dose from X-ray was not negligible because of the large number of X-ray images. A dose monitoring program can be useful for calculating radiation doses in patients with cancer.
منابع مشابه
Assessment of compliance levels of effective doses in pediatric CT
Introduction: Computed tomography (CT) is a medical imaging modality that produces 3-D cross-sectional images of tissues using several X-ray projections at different angles. Since its introduction in the 1970s, CT usage has been on the increase for both adults and pediatrics. A major challenge of this modality is the high doses of radiation exposure to patients, especially in p...
متن کاملPatient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode
Background: X-ray computed tomography (CT) examinations deliver a significant amount of radiation doses to patients comparing to conventional radiography examinations. The objective of the current study was to analyze and investigate the average patient received dose from axial and spiral CT exams in a medical imaging center. Material and Methods: In this study, the patient imaging tec...
متن کاملEvaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry
Background: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT an...
متن کاملCumulative radiation exposure dose of diagnostic imaging studies in breast cancer patients
Background: Breast cancer is a common disease in radiation oncology. We evaluated the radiation dose received by breast cancer patients, an often-neglected concern. Materials and Methods: The total effective radiation dose in 101 breast cancer patients was calculated by summing the effective doses of individual diagnostic imaging tests from the first hospital visit to the initiation of radiothe...
متن کاملUncertainties in effective dose estimation for CT transmission scan in total body PET-CT imaging with Auto mA3D tube current modulation
Background: Positron Emission Tomography-Computed Tomography (PET-CT) is a useful hybrid imaging modality in the diagnosis of various malignancies. This modality imposes almost 20 mSv radiation dose to the patient. The purpose of the present study was to evaluate the uncertainties in calculated CT effective dose in TUBE CURRENT MODULATION-activated scans by Impact-Dose software. Materials and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Diagnostic and interventional radiology
دوره 22 4 شماره
صفحات -
تاریخ انتشار 2016