Space Charge Behavior in Paper Insulation Induced by Copper Sulfide in High-Voltage Direct Current Power Transformers

نویسندگان

  • Ruijin Liao
  • Lijun Yang
  • Yuan Yuan
چکیده

The main insulation system in high-voltage direct current (HVDC) transformer consists of oil-paper insulation. The formation of space charge in insulation paper is crucial for the dielectric strength. Unfortunately, space charge behavior changes because of the corrosive sulfur substance in oil. This paper presents the space charge behavior in insulation paper induced by copper sulfide generated by corrosive sulfur in insulation oil. Thermal aging tests of paper-wrapped copper strip called the pigtail model were conducted at 130 °C in laboratory. Scanning electron microscopy (SEM) was used to observe the surface of copper and paper. Pulse electroacoustic (PEA) and thermally stimulated current (TSC) methods were used to obtain the space charge behavior in paper. Results showed that both maximum and total amount of space charge increased for the insulation paper contaminated by semi-conductor chemical substance copper sulfide. The space charge decay rate of contaminated paper was significantly enhanced after the polarization voltage was removed. The TSC results revealed that copper sulfide increased the trap density and lowered the shallow trap energy levels. These results contributed to charge transportation by de-trapping and trapping processes. This improved charge transportation could be the main reason for the decreased breakdown voltage of paper insulation material. OPEN ACCESS Energies 2015, 8 8111

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influences of Corrosive Sulfur on Copper Wires and Oil-Paper Insulation in Transformers

Oil-impregnated paper is widely used in power transmission equipment as a reliable insulation. However, copper sulphide deposition on oil-paper insulation can lead to insulation failures in power transformers. This paper presents the influences of copper sulfur corrosion and copper sulphide deposition on copper wires and oil-paper insulation in power transformers. Thermal aging tests of paper-w...

متن کامل

Space Charge Accumulation under the Effects of Temperature Gradient on Solid Dielectric Dc Cable

It is well known that existence and accumulation of space charge within the insulating material poses threat to the reliability in the operation of dc power cables. When the cables are loaded under high voltage direct current (HVDC), temperature gradient is developed across the insulation material. In this paper, commercial ac XLPE power cables were used under an application voltage of 80 kV dc...

متن کامل

Progress of Space Charge Research on Oil-Paper Insulation Using Pulsed Electroacoustic Techniques

This paper focuses on the space charge behavior in oil-paper insulation systems used in power transformers. It begins with the importance of understanding the space charge behavior in oil-paper insulation systems, followed by the introduction of the pulsed electrostatic technique (PEA). After that, the research progress on the space charge behavior of oil-paper insulation during the recent twen...

متن کامل

Fabrication of Al2O3 Nano-Structure Functional Film on a Cellulose Insulation Polymer Surface and Its Space Charge Suppression Effect

Cellulose insulation polymer (paper/pressboard) has been widely used in high voltage direct current (HVDC) transformers. One of the most challenging issues in the insulation material used for HVDC equipment is the space charge accumulation. Effective ways to suppress the space charge injection/accumulation in insulation material is currently a popular research topic. In this study, an aluminium...

متن کامل

Current State of Surge Testing Induction Machines

Surge testing of motor coils has been an industry practice since J. L. Rylander published “A High Frequency Voltage Test for Insulation of Rotating Electrical Apparatus” in Transactions of the AIEE, in February of 1926. Since that time the use of surge testing to diagnose failing or damaged insulation in motors has advanced greatly. In 1926, the indication of a turn-turn insulation failure was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015