Balanced Active and Reactive Control Applied to a Grid Connected Five Level Inverter
نویسندگان
چکیده
This paper presents a balanced active and reactive power control, using a Phase Locked Loop for synchronization, and applied to a grid connected Five Level Inverter. The energy source of the system can be a photovoltaic generator or a wind turbine. We size the passive elements of the system and explain the value of the system architecture using a Five Level Inverter when compared to a classical grid connected system. We also compare the balanced active and reactive power control to an unbalanced active and reactive power control. The simulation results obtained by using Matlab Simulink and Simpowersystems are presented and discussed in this paper. Keywords—Balanced control; grid connected system; multilevel inverter
منابع مشابه
A Grid-Connected PV Inverter with Compensation of Load Active and Reactive Power Imbalance for Distribution Networks
Load balancing is an important issue in distributed systems. In addition, using distributed generation sources such as photovoltaic is increasing. Power electronic converters are main interfaces between the sources and the grid. In this paper, a method has been proposed to reduce the load imbalancing in distribution networks using PV Grid Interface Converter. Two DC/DC and DC/AC converters have...
متن کاملModel Predictive Control of Distributed Energy Resources with Predictive Set-Points for Grid-Connected Operation
This paper proposes an MPC - based (model predictive control) scheme to control active and reactive powers of DERs (distributed energy resources) in a grid - connected mode (either through a bus with its associated loads as a PCC (point of common coupling) or an MG (micro - grid)). DER may be a DG (distributed generation) or an ESS (energy storage system). In the proposed scheme, the set - poin...
متن کاملDesign of A Single-Phase Transformerless Grid-Connected PV Inverter Considering Reduced Leakage Current and LVRT Grid Codes
A new single-phase transformerless grid-connected PV inverter is presented in this paper. Investigations in transformerless grid-connected PV inverters indicate the existence of the leakage current is directly related to the variable common-mode voltage (CMV), which is presented in detail. On the other hand, in recent years it has become mandatory for the transformerless grid-connected PV inver...
متن کاملA New Approach for Reactive Power Control of Single Phase Transformerless Inverter to Modify Power Quality in Stand Alone Micro-Grids with Current Leakage Elimination
Nowadays there has been an increasing interest in transformerless inverter for grid-connected photovoltaic (PV) system due to low cost, high efficiency and light weight. One of the reasons describe the grid behavior is capability of reactive power control by inverter. According to the standard VDE-AR-N 4105, grid-tied PV inverter of power rating below 3.68KVA, should attain power factor (PF) fr...
متن کاملReactive and Active Power Control of Grid WECS Based on DFIG and Energy Storage System under both Balanced and Unbalanced Grid Conditions
This paper focuses on improving the active and reactive power control of Wind Energy Conversion System (WECS) by employing the Battery Energy Storage System (BESS) and controlling the frequency and voltage regulation instantaneously. The proposed power control scheme is composed of two control loops so that they are implemented and designed for active power control and controlling the reactive ...