A novel suture method to place and adjust peripheral nerve catheters†
نویسندگان
چکیده
We have developed a peripheral nerve catheter, attached to a needle, which works like an adjustable suture. We used in-plane ultrasound guidance to place 45 catheters close to the femoral, saphenous, sciatic and distal tibial nerves in cadaver legs. We displaced catheters after their initial placement and then attempted to return them to their original positions. We used ultrasound to evaluate the initial and secondary catheter placements and the spread of injectate around the nerves. In 10 cases, we confirmed catheter position by magnetic resonance imaging. We judged 43/45 initial placements successful and 42/43 secondary placements successful by ultrasound, confirmed in 10/10 cases by magnetic resonance imaging.
منابع مشابه
Introduction of a New Suture Method in Repair of Peripheral Nerves Injured with a Sharp Mechanism
Background: The standard method for repair of an injured peripheal nerve is epineural repair with separate sutures. Herein we describe a method in which the nerve is sutured with continous sutures. In fact this method has not been utilized for nerve repair previously and our purpose was to compare it to the standard method. If it proved to be successful it would replace the standard method in...
متن کاملMorphological Identification of Cell Death in Dorsal Root Ganglion Neurons Following Peripheral Nerve injury and repair in adult rat
Background: Axotomy causes sensory neuronal loss. Reconnection of proximal and distal nerve ends by surgical repair improves neuronal survival. It is important to know the morphology of primary sensory neurons after the surgical repair of their peripheral processes. Methods: Animals (male Wistar rats) were exposed to models of sciatic nerve transection, direct epineurial suture repair of sciati...
متن کاملUse of ultrasound guidance to remove entrapped stimulating popliteal catheters.
Peripheral nerve catheters are beneficial for continuous pain relief following surgery or trauma to an extremity. However, spring-loaded peripheral nerve catheters can become uncoiled and entrapped, resulting in difficulty in catheter removal. We present two cases where ultrasound guidance provided significant assistance in the safe removal of entrapped peripheral nerve catheters without neurol...
متن کاملMorphometeric Study of Primary Sensory Neurons following Surgical Repair of Sciatic Nerve
Objective: Peripheral nerve transection causes neuonal cell death. Effects of surgical nerve repair on survival of primary sensory neurons was to be studied. Methodology: This is a morphometeric study of dorsal root ganglion neurons of adult rats by Hoechst staining conducted at Neuroscience laboratory and Cellular and Molecular Center, Medical faculty, Iran University of Medical Sciences. Mode...
متن کاملComplications of Peripheral Intravenous Catheters During 72 Hours After Insertion
Introduction: Peripheral Intravenous catheterization is the most commonly used invasive treatment method in patients admitted to the hospitals, but it has some complications. The indwell time of catheter is one of the factors associated with the occurrence of complications, especially phlebitis. In spite of the instructions for replacing the catheters after 72 hours, sometimes the complications...
متن کامل