Wide velocity range Doppler optical microangiography using optimized step-scanning protocol with phase variance mask.

نویسندگان

  • Lei Shi
  • Jia Qin
  • Roberto Reif
  • Ruikang K Wang
چکیده

We propose a simple and optimized method for acquiring a wide velocity range of blood flow using Doppler optical microangiography. After characterizing the behavior of the scanner in the fast scan axis, a step-scanning protocol is developed by utilizing repeated A-scans at each step. Multiple velocity range images are obtained by the high-pass filtering and Doppler processing of complex signals between A-scans within each step with different time intervals. A phase variance mask is then employed to segment meaningful Doppler flow signals from noisy phase background. The technique is demonstrated by imaging in vivo mouse brain with skull left intact to provide bidirectional images of cerebral blood flow with high quality and wide velocity range.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High speed, wide velocity dynamic range Doppler optical coherence tomography (Part V): Optimal utilization of multi-beam scanning for Doppler and speckle variance microvascular imaging.

In this paper, a multi-beam scanning technique is proposed to optimize the microvascular images of human skin obtained with Doppler effect based methods and speckle variance processing. Flow phantom experiments were performed to investigate the suitability for combining multi-beam data to achieve enhanced microvascular imaging. To our surprise, the highly variable spot sizes (ranging from 13 to...

متن کامل

High speed, wide velocity dynamic range Doppler optical coherence tomography (Part II): Imaging in vivo cardiac dynamics of Xenopus laevis.

We previously reported a Doppler optical coherence tomography (DOCT) system design [1] for high-speed imaging with wide velocity dynamic range (up to 28.5 dB when acquiring 8 frames per second), operating at 1.3 m with a coherence length of 13.5 m. Using a developmental biology model (Xenopus laevis), here we test the DOCT system's ability to image cardiac dynamics in an embryo in vivo, with a ...

متن کامل

Real-time bulk-motion-correction free Doppler variance optical coherence tomography for choroidal capillary vasculature imaging

In this paper, we analyze the retinal and choroidal blood vasculature in the posterior segment of the human eye with optimized color Doppler and Doppler variance optical coherence tomography. Depth-resolved structure, color Doppler and Doppler variance images are compared. Blood vessels down to the capillary level were detected and visualized with the optimized optical coherence color Doppler a...

متن کامل

High speed, wide velocity dynamic range Doppler optical coherence tomography (Part III): in vivo endoscopic imaging of blood flow in the rat and human gastrointestinal tracts.

We previously described a fiber based Doppler optical coherence tomography system [1] capable of imaging embryo cardiac blood flow at 4~16 frames per second with wide velocity dynamic range [2]. Coupling this system to a linear scanning fiber optical catheter design that minimizes friction and vibrations, we report here the initial results of in vivo endoscopic Doppler optical coherence tomogra...

متن کامل

Frequency domain phase - resolved optical Doppler and Doppler variance tomography

Frequency domain phase-resolved optical Doppler tomography (ODT) was developed with Doppler variance imaging capability. It is shown that utilizing the frequency domain method, phase-resolved ODT can achieve much higher imaging speed and velocity dynamic range than the time domain method. Structural, Doppler and Doppler variance images of fluid flow through glass channels were quantified and bl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 18 10  شماره 

صفحات  -

تاریخ انتشار 2013