The aim of this review paper is to enlighten some recent progresses in quantum optical metrology in the part of quantum efficiency measurements of photo-detectors performed with bi-photon states. The intrinsic correlated nature of entangled photons from Spontaneous Parametric Down Conversion phenomenon has opened wide horizons to a new approach for the absolute measurement of photodetector quantum efficiency, outgoing the requirement for conventional standards of optical radiation; in particular the simultaneous feature of the creation of conjugated photons led to a well known technique of coincidence measurement, deeply understood and implemented for standard uses. On the other hand, based on manipulation of entanglement developed for Quantum Information protocols implementations, a new method has been proposed for quantum efficiency measurement, exploiting polarisation entanglement in addition to energy-momentum and time ones, that is based on conditioned polarisation state manipulation. In this review, after a general discussion on absolute photo-detector calibration, we compare these different methods, in order to give an accurate operational sketch of the absolute quantum efficiency measurement state of the art.
منابع مشابه
Absolute efficiency estimation of photon-number-resolving detectors using twin beams.
A nonclassical light source is used to demonstrate experimentally the absolute efficiency calibration of a photon-number-resolving detector. The photon-pair detector calibration method developed by Klyshko for single-photon detectors is generalized to take advantage of the higher dynamic range and additional information provided by photon-number-resolving detectors. This enables the use of brig...
متن کاملPhoton dosimetry based on selective data sampling for the NaI(TL) detector
Radiation detection is essential for determining of radiation dose. Depend on the detector and dosimetry method, detection process is performed in different levels. Pulse counting is the first level of detection. Typically, the output of a radiation detector for determining value of the radiation dose cannot be used directly. Through changing the response function or the readout detector, is tr...
متن کاملCalibrating photon-counting detectors to high accuracy: background and deadtime issues
When photon-counting detectors are calibrated in the presence of a background signal, deadtime effects can be significant and must be carefully accounted for to achieve high accuracy. We present a method for separating the correlated signal from the background signal that appropriately handles deadtime effects. This method includes consideration of pulse timing and afterpulsing issues that aris...
متن کاملEntangled-photon ellipsometry
Performing reliable measurements in optical metrology, such as those needed in ellipsometry, requires a calibrated source and detector, or a wellcharacterized reference sample. We present a novel interferometric technique to perform reliable ellipsometric measurements. This technique relies on the use of a non-classical optical source, namely polarization-entangled twin photons generated by spo...
متن کاملPhoton Counting and Energy Discriminating X-Ray Detectors - Benefits and Applications
Since a few years the direct detection of X-ray photons into electrical signals is possible by usage of highly absorbing photo conducting materials (e.g. CdTe) as detection layer of an underlying CMOS semiconductor X-ray detector. Even NDT energies up to 400 keV are possible today, as well. The image sharpness and absorption efficiency is improved by the replacement of the unsharp scintillation...