Limitation of glucose oxidase method of glucose estimation in jaundiced neonates.
نویسندگان
چکیده
The most widely used method for estimation of plasma glucose is that adopted by Trinder's using glucose oxidase-peroxidase (GOD-POD) system. This method gives much lower blood glucose values with blood samples of neonatal jaundice (plasma bilirubin level > 10 mg/dL) of age 10 +/- 5 daysthan with samples of neonates of the same age group without jaundice or older children suffering from other diseases like acute respiratory distress, septicemia.
منابع مشابه
A Simple Image Analysis Method for Determination of Glucose by using Glucose Oxidase CdTe/TGA Quantum Dots
Glucose, as the major energy source in cellular metabolism, plays an important role in the natural growth of cells. Herein, a simple, rapid and low-cost method for the glucose determination by utilizing glucose oxidase and CdTe/thioglycolic acid (TGA) quantum dots (QDs) on a thin layer chromatography (TLC) plate has been described. The detection was based on the combination of the glucose enzym...
متن کاملTransformation and expression of Penicillium funicolusum glucose oxidase gene in yeast
Glucose oxidase is an important enzyme hydrolyzing for its hydrolyzing activity on glucos. It possesses and has a wide board of applications in different industries such as bakery, pharmaceutical, plant pathology and biosensors. In this study, yeast (Saccharomyces cerevisiae) was transformed successfully by the glucose oxidase gene (gox) obtained from Penicillium funicolusum. The secreted gluco...
متن کاملThe obtain optimum production conditions for Glucose Oxidase biosensor using software Qualtek-4
The Glucose Oxidase (Gox) electrochemical sensors were used to detect a little amount of glucose. In this paper, the pure platinum plate (length of 5 cm and a width of 3 mm), the Ag/AgCl electrode and platinum electrode (diameter of 1 mm) were applied as a working electrode (W.E), reference electrode and auxiliary electrode sequential. Factors measured, glucose concentration and pH is Phosphate...
متن کاملThe obtain optimum production conditions for Glucose Oxidase biosensor using software Qualtek-4
The Glucose Oxidase (Gox) electrochemical sensors were used to detect a little amount of glucose. In this paper, the pure platinum plate (length of 5 cm and a width of 3 mm), the Ag/AgCl electrode and platinum electrode (diameter of 1 mm) were applied as a working electrode (W.E), reference electrode and auxiliary electrode sequential. Factors measured, glucose concentration and pH is Phosphate...
متن کاملRemoval of Malachite Green by Using Immobilized Glucose Oxidase Onto Silica Nanostructure-Coated Silver Metal-Foam
Enzymes Immobilization onto different types of the substrate could be helpful in various applicationsof biomedical devices and biosensors. Enzyme activity and stability could be affected by support andmethod of immobilization. In this study, the silver metal foam was successfully synthesized by thesoft-shell method and then was coated with silica. Then, glucose oxidase (GOx) immobilized on nonc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Indian journal of experimental biology
دوره 44 3 شماره
صفحات -
تاریخ انتشار 2006